CU 7702 4P / 2x4P F8
Data cable, S/FTP, Category 7A, AWG22, Euroclass Cca
1300 MHz
1 Inner conductor: AWG22 Bare copper wire
2 PE insulated conductor: 1.5 mm ∅
3 Screen (pair): Alu PETP foil
4 Overall screen: Tinned braided copper
5 Outer sheath: FRNC/LSOH orange RAL 2003












Product variants & stock
Download
Article No. | Stock | Product | Reaction to fire | Dimensions n x p x [mm (AWG)] | Outer sheath dimensions [mm] | CU rate [kg/km] | Weight [kg/km] | Fire load [kWh/m] | Packing unit | GTIN / EAN |
---|---|---|---|---|---|---|---|---|---|---|
17739002CL | CU 7702 2x4P | Cca-s1b,d1,a1 | 2 x (4 x 2 x 0.62 (AWG22)) | 7.6 x 16.2 | 69.8 | 127.4 | 0.36 | 500 m drum | 40393910043402 | |
17740000CL | CU 7702 4P | Cca-s1a,d1,a1 | 4 x 2 x 0.62 (AWG22) | 7.4 | 35 | 57.5 | 0.146 | 500 m drum | 40393910043280 | |
17740000CK | CU 7702 4P | Cca-s1a,d1,a1 | 4 x 2 x 0.62 (AWG22) | 7.4 | 34.9 | 57.5 | 0.146 | 1000 m drum | 40393910043297 | |
17739000CL | CU 7702 2x4P | Cca-s1,d1,a1 | 2 x (4 x 2 x 0.62 (AWG22)) | 7.6 x 16.2 | 69.8 | 127.1 | 0.36 | 500 m drum | 40393910043464 |
Technical specifications
Electrically and mechanically superior quality Cat.7A data cable - exceeds the requirements of ISO/IEC 11801, IEC 61156-5, IEC 61156-7, EN 50173-1 and prEN 50288-9-1.
Excellent shielding effect due to individually screened pairs and overall copper braid.
Easy identification of wires thanks to longitudinal colour markings.
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.
Excellent shielding effect due to individually screened pairs and overall copper braid.
Easy identification of wires thanks to longitudinal colour markings.
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.
Minimum bending radius (during installation) | 64 mm |
---|---|
Tensile strength (2x4P) | 240 N |
Tensile strength (4P) | 120 N |
Minimum number of impacts | 10 |
Minimal crush resistance / 10cm | 1000 N |
AWG | 22 |
Solid / Flex | Solid wire |
Minimum bending radius (permanently installed) | 32 mm |
Data cable for structured premises cabling. For the transmission of digital and analogue voice, video and data signals. Suitable for all ICT network applications up to class FA applications (1000 MHz) in accordance with EN 50173-1 and ISO/IEC 11801 and for the transmission of broadband signals (such as cable TV) in accordance with IEC 15018. Due to the increased wire section eminently suited for Power over Ethernet (PoE) / PoE+ and 4PPoE up to 100W. |
Category | Cat.7A |
---|---|
GBit/s | Up to 10 Gbit/s |
Loop resistance at 20 °C | 116 Ω/km |
Operating capacity | 43 pF/m |
Impedance at 100 MHz, ±5Ω | 100 Ω |
NVP % | 76 |
Delay skew | 15 ns/100 m |
Shielding | shielded |
Near end unbalance attenuation LCL at 1-600 MHz | 40 dB |
Transfer impedance 1/10/30 MHz | < 5/5/8 mΩ/m |
Coupling attenuation | 85 dB |
Segregation class | d |
Installation temperature | 0 °C - +50 °C |
---|---|
Operating temperature | -20 °C - +60 °C |
Wire colour | white/blue-white, white/orange-white, white/green-white, white/brown-white (with length stripes) |
Imprint | DATWYLER «cable type» «additional text» «batch number» «meter marks» |
Field of application | Indoor |
Reaction to fire | EN 13501-6 |
---|---|
Euroclass | Cca |
Smoke density | IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Section 4.3.3 SD |
Zero halogen no corrosive gases | IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Section 4.3.3 SA |
Flame propagation | IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Section 4.3.3 F1 |
Flame spread | IEC 60332-3-24, EN 60332-3-24, AREI-RGIE Section 4.3.3 F2 |
Cables standard | ISO/IEC 61156-5, EN 50288-9-1 |
Cat./Class | Cat.7A / Class FA |
PoE | IEEE 802.3bt Type 4 (100W) |
Outer sheath material | FRNC/LSZH |
---|---|
Outer sheath colour | orange |
Documentation
-
Transmission Parameter
Download PDF [ 539.83 KB ]
-
GHMT PVP Certificates
Download PDF [ 248.255 KB ]
-
GHMT PVP Certificates
Download PDF [ 229.19 KB ]
-
Tender text
Download UNKNOWN [ 70.65 KB ]
-
Tender text
Download UNKNOWN [ 60.783 KB ]
-
Tender text
Download UNKNOWN [ 63.9 KB ]
-
Tender text
Download UNKNOWN [ 62.41 KB ]
-
GHMT Type Approval Certificate
Download PDF [ 241.233 KB ]
-
GHMT Type Approval Certificate
Download PDF [ 246.93 KB ]
-
Datasheet
Download PDF [ 178.736 KB ]
-
Datasheet
Download PDF [ 179.933 KB ]
-
Datasheet
Download PDF [ 179.779 KB ]
-
Datasheet
Download PDF [ 179.263 KB ]
-
Datasheet
Download PDF [ 179.093 KB ]
-
Datasheet
Download PDF [ 178.951 KB ]