FO Indoor FTTH STB / I-V(ZN)H

2.8 mm, LS0H, Euroclass Dca
Semi-tight buffer
flame retardant - IEC 60332.1
in accordance with IEC 60794-2-20

1 Fibre
2 Semi-tight buffer: 600 µm
3 Aramid yarn
4 LS0H sheath

04_Propagation 05_Spread- 06_Density 08_System- 03_LS0H CPR_Dca CPR_Eca

Product variants & stock

Article No. Stock ProductReaction to fireOuter sheath colourFibre typeFibre categoryOuter sheath diameter [mm]Bending radius [mm]CU rate [kg/km]Weight [kg/km]Tensile load [N]Crush resistance short term [N]Fire load [kWh/m]Packing unitGTIN / EAN
19341000DZ
FO Indoor FTTH STBDca-s2,d1,a1yellowE9/125 G.652.D BLOOS22.825084005000.043by the metre40393910026276
19440500DZ
FO Indoor FTTH STBDca-s2,d1,a1heather violetG50/125 OM4OM42.825084005000.043by the metre40393910022193

Technical specifications

Easy to handle fibre optic cable with 4 optical fibres. Very small outer diameter (2.8 mm) due to innovative construction with 0.6 mm semi-tight buffers. Flame retardant halogen-free LS0H sheath. Very low fire load. Robust sheath for easy installation into tube systems occupied by other cables.
Maximum number of fibres 4
Installation temperature -10 °C - +50 °C
Operating temperature -20 °C - +60 °C
Imprint DATWYLER «cable type» «Datwyler designation» «DIN designation» «no. of fibres» «fibre type» «add. text» «batch no.» «meter marks»
Field of application Indoor
Indoor cabling for Fibre to the Home (FTTH) applications.
Indoor cabling for data network and building automation applications.
Connection cable between building entry point (BEP) and FO data outlet.
Suitable for laying in cable trays, ducts and vertical shafts.
For direct termination with FO connectors. Suitable for splicing.
Tensile performance IEC 60794-1-21 E1
Crush resistance IEC 60794-1-21 E3
Impact IEC 60794-1-21 E4
Repeated bending IEC 60794-1-21 E6
Torsion IEC 60794-1-21 E7
Bend IEC 60794-1-21 E11
Temperature cycling IEC 60794-1-22 F1
Reaction to fire EN 13501-6
Euroclass Dca
Smoke density IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2
Flame propagation IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
Outer sheath material FRNC/LSZH

Documentation