CU 7702 4P FRNC/GG/FRNC
Data cable, S/FTP, Category 7A, AWG22, Euroclass Cca
1300 MHz
1 Inner conductor: AWG22 Bare copper wire
2 PE insulated conductor: 1.52 mm Ø
3 Screen (pair): Alu PETP foil
4 Overall screen: Tinned braided copper
5 Sheath: FRNC/LS0H orange RAL 2003
6 Rodent protection: with glass rovings
7 Ripcord
8 Outer sheath: FRNC/LS0H black










Product variants & stock
Download
Article No. | Stock | Product | Reaction to fire | Dimensions n x p x [mm (AWG)] | Outer sheath dimensions [mm] | CU rate [kg/km] | Weight [kg/km] | Fire load [kWh/m] | Packing unit | GTIN / EAN |
---|---|---|---|---|---|---|---|---|---|---|
19435400CZ | CU 7702 4P | Cca-s1a,d1,a1 | 4 x 2 x 0.62 (AWG22) | 12.0 | 34.9 | 167 | 0.55 | by the metre | 40393910022704 |
Technical specifications
Applicable for outdoor installation due to rodent protection and UV resistant outer cable sheath.
Robust cable design with a high mechanical stability.
Electrically and mechanically superior quality Cat.7A data cable - exceeds the requirements of ISO/IEC 11801-1, IEC 61156-5, EN 50173-1 and EN 50288-9-1.
Excellent shielding effect due to individually screened pairs and overall copper braid.
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801-1.
Robust cable design with a high mechanical stability.
Electrically and mechanically superior quality Cat.7A data cable - exceeds the requirements of ISO/IEC 11801-1, IEC 61156-5, EN 50173-1 and EN 50288-9-1.
Excellent shielding effect due to individually screened pairs and overall copper braid.
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801-1.
Tensile strength (4P) | 150 N |
---|---|
Minimum bending radius (during installation) | 96 mm |
Minimal crush resistance / 10cm | 1000 N |
Minimum number of impacts | 10 |
AWG | 22 |
Solid / Flex | Solid wire |
Minimum bending radius (permanently installed) | 48 mm |
Data cable for structured premise cabling with enhanced mechanical and fire protection performance. Designed for installation in Tunnels, Metro-Systems and Buildings with augmented requirements. With rodent protection and UV protected outer sheath. Installation in ducts, tubes and on cable support systems. Suitable for all ICT network applications up to class FA applications (1000 MHz) in accordance with EN 50173-1 and ISO/IEC 11801. Supports 10Base-T, 100Base-T, 1GBase-T (1000Base-T) and 10GBase-T. Applicable for Power over Ethernet PoE / PoE+ / 4PPoE. |
Category | Cat.7A |
---|---|
GBit/s | Up to 10 Gbit/s |
Loop resistance at 20 °C | 116 Ω/km |
Operating capacity | 43 pF/m |
Impedance at 100 MHz, ±5Ω | 100 Ω |
NVP % | 76 |
Delay skew | 15 ns/100 m |
Shielding | shielded |
Near end unbalance attenuation LCL at 1-600 MHz | 40 dB |
Transfer impedance 1/10/30 MHz | < 5/5/8 mΩ/m |
Coupling attenuation | 85 dB |
Segregation class | d |
Installation temperature | 0 °C - +50 °C |
---|---|
Operating temperature | -20 °C - +60 °C |
Wire colour | white/blue-white, white/orange-white, white/green-white, white/brown-white (with length stripes) |
Imprint | DATWYLER «cable type» «additional text» «batch number» «meter marks» |
Field of application | Outdoor |
Reaction to fire | EN 13501-6 |
---|---|
Euroclass | Cca |
Smoke density | IEC 61034-1/-2, EN 61034-1/-2 |
Zero halogen no corrosive gases | IEC 60754-1/-2, EN 60754-1/-2 |
Flame propagation | IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2 |
Cables standard | ISO/IEC 61156-5, EN 50288-9-1 |
Cat./Class | Cat.7A / Class FA |
PoE | IEEE 802.3bt Type 4 (100W) |
Outer sheath material | FRNC/LSZH |
---|---|
Outer sheath colour | black |