Back to: Outdoor cable

FO Outdoor wbKT S-Micro / A-DQ(ZN)2Y

S-Micro, up to 288 fibres, Euroclass Fca
metal-free, non-armoured, longitudinally watertight

1 ≤ 12 fibres
2 Loose tube
3 Aramid yarn
4 Ripcord
5 HDPE sheath

Description

Highly compact, metal-free fibre optic outdoor cable with with up to 288 fibres in stranded loose tubes and with dry interstices.
Easily cut-back, installation-friendly cable construction.

  • FTTx, Fibre-to-the-home networks.
    Optimised for injection into microducts.
  • Outer sheath material HDPE
  • Armouring (rodent protection) non-armoured
  • Installation temperature -5 °C - +50 °C
  • Storage temperature -25 °C - +70 °C
  • Operating temperature -25 °C - +70 °C
  • Field of application Outdoor
  • Imprint DATWYLER «cable type» «Datwyler designation» «DIN designation» «no. of fibres» «fibre type» «add. text» «batch no.» «meter marks»
  • Maximum number of fibres 288
  • Datwyler recommends blowing in micro and mini cables in an ambient temperature range from -2°C to +35°C.For installation, a blow-in device with a rubber pull-in bead is recommended.
  • Tensile performance IEC 60794-1-21 E1
  • Crush resistance IEC 60794-1-21 E3
  • Impact IEC 60794-1-21 E4
  • Repeated bending IEC 60794-1-21 E6
  • Torsion IEC 60794-1-21 E7
  • Bend IEC 60794-1-21 E11
  • Temperature cycling IEC 60794-1-22 F1
  • Water penetration IEC 60794-1-22 F5
  • Reaction to fire (Euroclasses) EN 13501-6: Fca
  • Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2

Documentation

ENDENLFRCNESIT
Datasheet Datasheet Datasheet Datasheet Datasheet file-icon Datasheet Datasheet
Tender text file-icon Tender text file-icon file-icon file-icon file-icon file-icon

Versions

Article No.StockProductReaction To FireOuter sheath colourNumber of FibresFibre typeOuter sheath diameter [mm]Bending radius [mm]Weight [kg/km]Tensile load [N]Crush resistance short term [N]Crush resistance continuous [N]Fire load [kWh/m]Packing unitFibre categoryFibres per loose tubeLoose tube constructionNumber of used loose tubes
19269300FZ FO Outdoor S-Micro 2x12Fcablack24E9/125 G.652.D BLO4.2 mm250 mm1775012004000.09 kWh/mby the metreOS21222
19215000FZ FO Outdoor S-Micro 4x12Fcablack48E9/125 G.652.D BLO4.2 mm250 mm1775012004000.09 kWh/mby the metreOS21244
19215900FZ FO Outdoor S-Micro 8x12Fcablack96E9/125 G.652.D BLO6.6 mm250 mm42190012004000.18 kWh/mby the metreOS21288
19709000FZ FO Outdoor S-Micro 12x12Fcablack144E9/125 G.652.D BLO8.2 mm300 mm58190012004000.345 kWh/mby the metreOS2121212
19450000FZ FO Outdoor S-Micro 6x24Fcablack144E9/125 G.652.D BLO6.5 mm250 mm33130012004000.188 kWh/mby the metreOS22466
19339600FZ FO Outdoor S-Micro 8x24Fcablack192E9/125 G.652.D BLO8.4 mm300 mm56190012004000.325 kWh/mby the metreOS22498
19262500FZ FO Outdoor S-Micro 9x24Fcablack216E9/125 G.652.D BLO8.4 mm300 mm58190012004000.325 kWh/mby the metreOS22499
19600000FZ FO Outdoor S-Micro 12x24Fcablack288E9/125 G.652.D BLO10.4 mm300 mm88290012004000.562 kWh/mby the metreOS2241212