FO Outdoor ZKT Micro / A-DQ(ZN)2Y, Fca

Micro, up to 24 fibres, Euroclass Fca
metal-free, non-armoured,
dry interstices, longitudinally watertight

1 ≤ 24 fibres
2 Loose tube
3 Aramid yarn
4 Ripcord
5 HDPE sheath

04_Propagation- 05_Spread- 06_Density- 08_System- 03_LS0H CPR_Fca

Product variants & stock

Article No. Stock Loose tube constructionFibres per loose tubeNumber of used loose tubesProductReaction to fireOuter sheath colourNumber of fibresFibre typeFibre categoryOuter sheath diameter [mm]Bending radius [mm]CU rate [kg/km]Weight [kg/km]Tensile load [N]Crush resistance short term [N]Crush resistance continuous [N]Fire load [kWh/m]Packing unitGTIN / EAN
19170200FZ
121FO Outdoor Micro 1x2Fcablack/orange2E9/125 G.652.D BLOOS2410001350016006000.165by the metre40393910029925
19065800FZ
141FO Outdoor Micro 1x4Fcablack/orange4E9/125 G.652.D BLOOS2410001350016006000.165by the metre40393910032482
19170300FZ
161FO Outdoor Micro 1x6Fcablack/orange6E9/125 G.652.D BLOOS2410001350016006000.165by the metre40393910029918
19170400FZ
181FO Outdoor Micro 1x8Fcablack/orange8E9/125 G.652.D BLOOS2410001350016006000.165by the metre40393910029901
19170500FZ
1101FO Outdoor Micro 1x10Fcablack/orange10E9/125 G.652.D BLOOS2410001350016006000.165by the metre40393910029895
19022700FZ
1121FO Outdoor Micro 1x12Fcablack/orange12E9/125 G.652.D BLOOS2410001450016006000.165by the metre40393910033199
19123500FZ
1241FO Outdoor Micro 1x24Fcablack/orange24E9/125 G.652.D BLOOS2410001550016006000.165by the metre40393910031546

Technical specifications

Very thin, metal-free fiber optic outdoor cable with up to 24 fibres in one central loose tube. Easily cut-back, installation friendly cable construction.
Maximum number of fibres 24
Field of application Outdoor
Installation temperature -5 °C - +50 °C
Storage temperature -40 °C - +70 °C
Operating temperature -40 °C - +70 °C
Imprint DATWYLER FO Outdoor ZKT Micro / A-DQ(ZN)2Y «No. of fibres» «Fibre type» «Batch no.» MADE IN SWITZERLAND «Receiver wave receiver wave» «Meter marks»
FTTx, Fibre-to-the-home networks.
Optimised for injection into microducts.
Datwyler recommends blowing in micro and mini cables in an ambient temperature range from -2°C to +35°C.
For installation, a blow-in device with a rubber pull-in bead is recommended.
Tensile performance IEC 60794-1-21 E1
Crush resistance IEC 60794-1-21 E3
Impact IEC 60794-1-21 E4
Repeated bending IEC 60794-1-21 E6
Torsion IEC 60794-1-21 E7
Bend IEC 60794-1-21 E11
Temperature cycling IEC 60794-1-22 F1
Water penetration IEC 60794-1-22 F5
Reaction to fire EN 13501-6
Euroclass Fca
Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2
Armouring (rodent protection) non-armoured
Outer sheath material HDPE

Documentation