Back to: Outdoor cable





FO Outdoor ZT S-Micro / A-D2Y
S-Micro, up to 24 fibres, Euroclass Fca
metal-free, non-armoured, dry interstices, longitudinally watertight
1 ≤ 24 fibres
2 PE sheath






Description
Very thin, metal-free fibre optic outdoor cable with up to 24 fibres in one central loose tube.
Easily cut back, installation friendly cable construction.
-
FTTx, Fibre-to-the-home networks.
Optimised for injection into microducts.
- Armouring (rodent protection) non-armoured
- Installation temperature -5 °C - +50 °C
- Storage temperature -25 °C - +70 °C
- Operating temperature -25 °C - +70 °C
- Outer sheath material PBT
- Imprint DATWYLER «cable type» «Datwyler designation» «DIN designation» «no. of fibres» «fibre type» «add. text» «batch no.» «meter marks»
- Field of application Outdoor
- Maximum number of fibres 24
- Datwyler recommends blowing in micro and mini cables in an ambient temperature range from -2°C to +35°C.For installation, a blow-in device with a rubber pull-in bead is recommended.
- Tensile performance IEC 60794-1-21 E1
- Crush resistance IEC 60794-1-21 E3
- Impact IEC 60794-1-21 E4
- Repeated bending IEC 60794-1-21 E6
- Torsion IEC 60794-1-21 E7
- Bend IEC 60794-1-21 E11
- Temperature cycling IEC 60794-1-22 F1
- Water penetration IEC 60794-1-22 F5
- Reaction to fire (Euroclasses) EN 13501-6: Fca
- Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2
- Kink IEC 60794-1-21 E10
Documentation
More Information
Versions
Article No. | Stock | Product | Reaction to fire | Outer sheath colour | Number of fibres | Fibre type | Outer sheath diameter [mm] | Bending radius [mm] | Weight [kg/km] | Tensile load [N] | Crush resistance short term [N] | Crush resistance continuous [N] | Fire load [kWh/m] | Packing unit | GTIN / EAN | Fibre category | Fibres per loose tube | Loose tube construction | Number of used loose tubes |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
19343400FZ
|
FO Outdoor S-Micro 1x4 | Fca | black | 4 | E9/125 G.652.D BLO | 2.4 | 40 | 5 | 100 | 1200 | 400 | 0.12 kWh/m | by the metre | 40393910026122 | OS2 | 4 | 1 | 1 | |
19604800FZ
|
FO Outdoor S-Micro 1x6 | Fca | black | 6 | E9/125 G.652.D BLO | 2.4 | 40 | 5 | 100 | 1200 | 400 | 0.12 kWh/m | by the metre | 40393910020434 | OS2 | 6 | 1 | 1 | |
19345900FZ
|
FO Outdoor S-Micro 1x6 | Fca | black | 6 | G50/125 OM3 | 2.4 | 40 | 5 | 100 | 1200 | 400 | 0.12 kWh/m | by the metre | 40393910026016 | OM3 | 6 | 1 | 1 | |
19346000FZ
|
FO Outdoor S-Micro 1x12 | Fca | black | 12 | E9/125 G.652.D BLO | 2.4 | 40 | 5 | 100 | 1200 | 400 | 0.12 kWh/m | by the metre | 40393910026009 | OS2 | 12 | 1 | 1 | |
19343500FZ
|
FO Outdoor S-Micro 1x12 | Fca | black | 12 | G50/125 OM4 | 2.4 | 40 | 5 | 100 | 1200 | 400 | 0.12 kWh/m | by the metre | 40393910026115 | OM4 | 12 | 1 | 1 | |
19343300FZ
|
FO Outdoor S-Micro 1x24 | Fca | black | 24 | E9/125 G.652.D BLO | 2.4 | 40 | 6 | 100 | 1200 | 400 | 0.12 kWh/m | by the metre | 40393910026139 | OS2 | 24 | 1 | 1 | |
19607000FZ
|
FO Outdoor S-Micro 1x24 | Fca | black | 24 | G50/125 OM4 | 2.4 | 40 | 6 | 100 | 1200 | 400 | 0.12 kWh/m | by the metre | 40393910020182 | OM4 | 24 | 1 | 1 |