FO Outdoor ZT S-Micro / A-D2Y

S-Micro, up to 24 fibres, Euroclass Fca
metal-free, non-armoured, dry interstices, longitudinally watertight

1 ≤ 24 fibres
2 PE sheath

04_Propagation- 05_Spread- 06_Density- 08_System- 03_LS0H CPR_Fca

Product variants & stock

Article No. Stock Loose tube constructionFibres per loose tubeNumber of used loose tubesProductReaction to fireOuter sheath colourNumber of fibresFibre typeFibre categoryOuter sheath diameter [mm]Bending radius [mm]CU rate [kg/km]Weight [kg/km]Tensile load [N]Crush resistance short term [N]Crush resistance continuous [N]Fire load [kWh/m]Packing unitGTIN / EAN
19343400FZ
141FO Outdoor S-Micro 1x4Fcablack4E9/125 G.652.D BLOOS22.4400510012004000.12by the metre40393910026122
19604800FZ
161FO Outdoor S-Micro 1x6Fcablack6E9/125 G.652.D BLOOS22.4400510012004000.12by the metre40393910020434
19345900FZ
161FO Outdoor S-Micro 1x6Fcablack6G50/125 OM3OM32.4400510012004000.12by the metre40393910026016
19346000FZ
1121FO Outdoor S-Micro 1x12Fcablack12E9/125 G.652.D BLOOS22.4400510012004000.12by the metre40393910026009
19343500FZ
1121FO Outdoor S-Micro 1x12Fcablack12G50/125 OM4OM42.4400510012004000.12by the metre40393910026115
19343300FZ
1241FO Outdoor S-Micro 1x24Fcablack24E9/125 G.652.D BLOOS22.4400610012004000.12by the metre40393910026139
19607000FZ
1241FO Outdoor S-Micro 1x24Fcablack24G50/125 OM4OM42.4400610012004000.12by the metre40393910020182

Technical specifications

Very thin, metal-free fibre optic outdoor cable with up to 24 fibres in one central loose tube. Easily cut back, installation friendly cable construction.
Maximum number of fibres 24
Field of application Outdoor
Installation temperature -5 °C - +50 °C
Storage temperature -25 °C - +70 °C
Operating temperature -25 °C - +70 °C
Imprint DATWYLER «cable type» «Datwyler designation» «DIN designation» «no. of fibres» «fibre type» «add. text» «batch no.» «meter marks»
FTTx, Fibre-to-the-home networks.
Optimised for injection into microducts.
Datwyler recommends blowing in micro and mini cables in an ambient temperature range from -2°C to +35°C.
For installation, a blow-in device with a rubber pull-in bead is recommended.
Tensile performance IEC 60794-1-21 E1
Crush resistance IEC 60794-1-21 E3
Impact IEC 60794-1-21 E4
Repeated bending IEC 60794-1-21 E6
Torsion IEC 60794-1-21 E7
Kink IEC 60794-1-21 E10
Bend IEC 60794-1-21 E11
Temperature cycling IEC 60794-1-22 F1
Water penetration IEC 60794-1-22 F5
Reaction to fire EN 13501-6
Euroclass Fca
Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2
Armouring (rodent protection) non-armoured
Outer sheath material PBT

Documentation