FO Outdoor ZGGT HP / A-DQ(ZN)B2Y

HighP Euroclass Fca
central tube design, metal-free,
longitudinally watertight, rodent protection

1 ≤ 24 fibres
2 Loose tube
3 Glass armour
4 Ripcord
5 HDPE sheath

Description

Robust, metal-free fibre optic outdoor cable with one central loose tube and up to 24 fibres.
High tensile strength and high radial load strength for the highest transmission security.
Lightweight and installation friendly cable construction.
Non-metallic rodent protection.
The two coloured ripcords are easy to identify and enable the safe opening of the cable sheath.
HDPE cable sheath, easy to lay.

  • For pulling in or blowing through thermoplastic duct systems.
    Suitable for laying in cable platforms, cable shafts
    and even in very complex cable trays.
    Direct burial.
  • Outer sheath material HDPE
  • Armouring (rodent protection) rodent protected
  • Installation temperature -10 °C - +50 °C
  • Storage temperature -40 °C - +70 °C
  • Operating temperature -40 °C - +70 °C
  • Field of application Outdoor
  • Imprint DATWYLER «cable type» «Datwyler designation» «DIN designation» «no. of fibres» «fibre type» «add. text» «batch no.» «meter marks»
  • Tensile performance IEC 60794-1-21 E1
  • Crush resistance IEC 60794-1-21 E3
  • Impact IEC 60794-1-21 E4
  • Repeated bending IEC 60794-1-21 E6
  • Torsion IEC 60794-1-21 E7
  • Bend IEC 60794-1-21 E11
  • Water penetration IEC 60794-1-22 F5
  • Reaction to fire (Euroclasses) EN 13501-6: Fca
  • Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2

Documentation

ENDENLFRCNESIT
Datasheet Datasheet Datasheet Datasheet Datasheet file-icon Datasheet Datasheet
GHMT PVP Certificates GHMT PVP Certificates GHMT PVP Certificates file-icon file-icon file-icon file-icon file-icon

Versions

Article No.StockProductReaction To FireOuter sheath colourNumber of FibresFibre typeOuter sheath diameter [mm]Bending radius [mm]Weight [kg\km]Tensile load [N]Crush resistance short term [N]Crush resistance continuous [N]Fire load [kWh\m]Packing unitFibre categoryFibres per loose tubeLoose tube constructionNumber of used loose tubes
19016600FZ FO Outdoor HP 1x4Fcablack4E9/125 G.652.D OS28.2 mm130 mm7525001000060000.558 kWh/mby the metreOS2411
19212100FZ FO Outdoor HP 1x4Fcablack4G50/125 OM38.2 mm130 mm7525001000060000.558 kWh/mby the metreOM3411
19608900FZ FO Outdoor HP 1x4Fcablack4G50/125 OM48.2 mm130 mm7525001000060000.558 kWh/mby the metreOM4411
19016700FZ FO Outdoor HP 1x6Fcablack6E9/125 G.652.D OS28.2 mm130 mm7525001000060000.558 kWh/mby the metreOS2611
19074700FZ FO Outdoor HP 1x6Fcablack6G50/125 OM38.2 mm130 mm7525001000060000.558 kWh/mby the metreOM3611
19016800FZ FO Outdoor HP 1x8Fcablack8E9/125 G.652.D OS28.2 mm130 mm7525001000060000.558 kWh/mby the metreOS2811
19016900FZ FO Outdoor HP 1x12Fcablack12E9/125 G.652.D OS28.2 mm130 mm7525001000060000.558 kWh/mby the metreOS21211
18636100FZ FO Outdoor HP 1x12Fcablack12G50/125 OM38.2 mm130 mm7525001000060000.558 kWh/mby the metreOM31211
19261000FZ FO Outdoor HP 1x12Fcablack12G50/125 OM48.2 mm130 mm7525001000060000.558 kWh/mby the metreOM41211
19014900FZ FO Outdoor HP 1x24Fcablack24E9/125 G.652.D OS28.6 mm135 mm8025001000060000.589 kWh/mby the metreOS22411
19264500FZ FO Outdoor HP 1x24Fcablack24G50/125 OM38.6 mm135 mm8025001000060000.589 kWh/mby the metreOM32411
19216700FZ FO Outdoor HP 1x24Fcablack24G50/125 OM48.6 mm135 mm8025001000060000.589 kWh/mby the metreOM42411