FO Universal wbGGFR Combi / U-DQS(ZN)BH

Combination cable with 3 stranded copper wires
dry interstices, rodent protection,
in accordance with IEC 60332.1 and IEC 60332.3 .C

1 Fibres
2 Copper wires
3 Glass armour
4 Ripcord
5 FR/LS0H sheath

04_Propagation 05_Spread 06_Density 08_System- 03_LS0H CPR_Eca CPR_Dca

Product variants & stock

Article No. Stock Loose tube constructionFibres per loose tubeNumber of used loose tubesProductReaction to fireOuter sheath colourNumber of fibresFibre typeFibre categoryOuter sheath diameter [mm]Bending radius [mm]CU rate [kg/km]Weight [kg/km]Tensile load [N]Crush resistance short term [N]Crush resistance continuous [N]Fire load [kWh/m]Packing unitGTIN / EAN
18635800DZ
121wbGGFR Combi 1x2 + 3x2.5 mm²Dca-s2,d1,a1black2E9/125 G.652.D OS2OS213.0200722423000300010000.774by the metre40393910039054

Technical specifications

The glass armour provides for a combined non-metallic rodent protection and strain relief. Two ripcords enable the safe opening of the cable sheath. Dry stranding interstices - easy handling. Flame retardant, flame resistant cable sheath.
Maximum number of fibres 2
Field of application Universal
Installation temperature -10 °C - +50 °C
Storage temperature -25 °C - +70 °C
Operating temperature -25 °C - +70 °C
Imprint DATWYLER «cable type» «Datwyler designation» «DIN designation» «no. of fibres» «fibre type» «add. text» «batch no.» «meter marks»
For indoor and outdoor use.
Camera combi cable in tunnels, underground railroads, large-scale industry.
Pulling in or blowing through thermoplastic ducts.
Laying on cable platforms and cable trays.
Tensile performance IEC 60794-1-21 E1
Crush resistance IEC 60794-1-21 E3
Impact IEC 60794-1-21 E4
Repeated bending IEC 60794-1-21 E6
Torsion IEC 60794-1-21 E7
Bend IEC 60794-1-21 E11
Temperature cycling IEC 60794-1-22 F1
Reaction to fire EN 13501-6
Euroclass Dca
Smoke density IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2
Flame propagation IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
Flame spread IEC 60332-3-24, EN 60332-3-24, VDE 0482-332-3-24
Outer sheath material FRNC/LSZH

Documentation