Back to: Copper cables

CU SPE 1P flex Industrial FRNC UL

Industrial data cable, S/FTP, AWG22/7, Euroclass Eca
600 MHz

1 Inner conductor: AWG22/7, stranded copper wires
2 PE insulated conductor: Ø 1.7 mm
3 Screen (pair): Alu PETP foil
4 Overall screen: Tinned braided copper
5 Outer sheath: FRNC/LSZH

Description

Electrically and mechanically high-quality 1-pair cable for Single Pair Ethernet (SPE) application and for frequencies up to 600 MHz.
Complies and exceeds the requirements of ISO/IEC 11801-1 Amd 1 “General Requirements”, ISO/IEC 11801-3 Amd 1 “Industrial Premises”, ISO/IEC 11801-6 Amd 1 “Distributed Building Services”, TR 11801-9906 “one pair channel” and IEC 61156-11 “Symmetrical single pair cables with transmission characteristics up to 600 MHz”.
Excellent shielding effectiveness due to individually screened pair and overall copper braid.
Compatible with all current Single Pair Ethernet connecting hardware in accordance with IEC 63171 series.

  • Flexible data cable with stranded conductor suitable for patch cords and equipment cords in a Single Pair Ethernet environment.
    For the transmission of digital and analogue data, voice and video signals.
    Suitable for IP based 2-wire bus applications with conductor wire size of AWG 22.
    Applicable for Power over Data Line (PoDL).
  • Outer sheath material FRNC/LSZH
  • Category Single pair Ethernet
  • Coupling attenuation 85 dB
  • Shielding shielded
  • Impedance at 100 MHz, ±5Ω 100 Ω
  • NVP % 78
  • operating capacity, 1km @ 800Hz 43 pF/m
  • Installation temperature 0 °C - +50 °C
  • Operating temperature -20 °C - +70 °C
  • Imprint DATWYLER «cable type» «additional text» «UL Info» «batch number» «meter marks»
  • Field of application Single pair Ethernet
  • Wire colour white/blue
  • AWG 22
  • Maximum tensile strength 25 N
  • Minimum bending radius permanently installed 22 mm
  • Solid / Flex Stranded wire (flexible)
  • Reaction to fire (Euroclasses) EN 13501-6: Eca
  • Smoke density IEC 61034-1/-2, EN 61034-1/-2
  • Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2
  • Flame propagation IEC 60332-1-2, EN 60332-1-2
  • Cables standard ISO/IEC 61156-11
  • Cat./Class Single pair Ethernet SPE and IEC 61156-11 guaranteed
  • PoDL (PoE) IEEE 802.3bu
  • UL certification UL 444, CMG

Documentation

EN DE NL FR CN ES IT
Datasheet Datasheet Datasheet Datasheet Datasheet file-icon Datasheet Datasheet

Versions

Article No. Stock Product AWGReaction to fireDimensions n x p x [mm² (AWG)]Outer sheath colourNumber of pairsNumber of coresOuter sheath dimensions [mm]CU rate [kg/km]Weight [kg/km]Number of cablesPacking unit
19471300EK CU SPE 1P AWG 22/7 AWG22/7 Eca 1 x 2 x 0.35 (AWG22/7) grey 1 2 5.1 16.1 34 1 1000 m drum