Enhanced Fire Safety Cable solid
Fire alarm cable, 300/500V
halogen-free, with improved fire characteristics,
BS 7629-1 and BS 5839-1 Enhanced
1 Conductor: solid
2 Insulation: Mica fire resistant tape
3 Silicon rubber
4 Drain wire: tinned copper
5 Shielding: Aluminium/polyester tape
6 Sheath: FRNC/LSZH
Product variants & stock
Article No. | Stock | Product | Outer sheath colour | Diameter mm² | Outer sheath diameter [mm] | CU rate [kg/km] | Resistance [Ω/km] | Voltage drop [Ω mV/A/m] | Weight [kg/km] | Fire load [kWh/m] | Packing unit | GTIN / EAN |
---|---|---|---|---|---|---|---|---|---|---|---|---|
18836810ZL | Enhanced Fire Safety Cable 2 x 1.5 | red | 1.5 | 8.6 | 43 | 12.1 | 29 | 115 | 0.19 | 500 m drum | 40393910095913 | |
18836810ZM | Enhanced Fire Safety Cable 2 x 1.5 | red | 1.5 | 8.6 | 43 | 12.1 | 29 | 115 | 0.19 | 200 m drum | 40393910095906 | |
18836810ZN | Enhanced Fire Safety Cable 2 x 1.5 | red | 1.5 | 8.6 | 43 | 12.1 | 29 | 115 | 0.19 | 100 m drum | 40393910095890 | |
18836910ZL | Enhanced Fire Safety Cable 2 x 1.5 | white | 1.5 | 8.6 | 43 | 12.1 | 29 | 115 | 0.19 | 500 m drum | 40393910095852 | |
18836910ZM | Enhanced Fire Safety Cable 2 x 1.5 | white | 1.5 | 8.6 | 43 | 12.1 | 29 | 115 | 0.19 | 200 m drum | 40393910095845 | |
18836910ZN | Enhanced Fire Safety Cable 2 x 1.5 | white | 1.5 | 8.6 | 43 | 12.1 | 29 | 115 | 0.19 | 100 m drum | 40393910095838 | |
18837010ZL | Enhanced Fire Safety Cable 2 x 2.5 | red | 2.5 | 9.9 | 72 | 7.41 | 18 | 160 | 0.26 | 500 m drum | 40393910095791 | |
18837010ZM | Enhanced Fire Safety Cable 2 x 2.5 | red | 2.5 | 9.9 | 72 | 7.41 | 18 | 160 | 0.26 | 200 m drum | 40393910095784 | |
18837010ZN | Enhanced Fire Safety Cable 2 x 2.5 | red | 2.5 | 9.9 | 72 | 7.41 | 18 | 160 | 0.26 | 100 m drum | 40393910095777 | |
18837110ZL | Enhanced Fire Safety Cable 2 x 2.5 | white | 2.5 | 9.9 | 72 | 7.41 | 18 | 160 | 0.26 | 500 m drum | 40393910095739 | |
18837110ZM | Enhanced Fire Safety Cable 2 x 2.5 | white | 2.5 | 9.9 | 72 | 7.41 | 18 | 160 | 0.26 | 200 m drum | 40393910095722 | |
18837110ZN | Enhanced Fire Safety Cable 2 x 2.5 | white | 2.5 | 9.9 | 72 | 7.41 | 18 | 160 | 0.26 | 100 m drum | 40393910095715 | |
19167910ZL | Enhanced Fire Safety Cable 4 x 1.5 | red | 1.5 | 10.1 | 72 | 12.1 | 29 | 180 | 0.28 | 500 m drum | 40393910095005 | |
19167910ZM | Enhanced Fire Safety Cable 4 x 1.5 | red | 1.5 | 10.1 | 72 | 12.1 | 29 | 180 | 0.28 | 200 m drum | 40393910094992 | |
19167910ZN | Enhanced Fire Safety Cable 4 x 1.5 | red | 1.5 | 10.1 | 72 | 12.1 | 29 | 180 | 0.28 | 100 m drum | 40393910094985 | |
19632910ZL | Enhanced Fire Safety Cable 4 x 1.5 | white | 1.5 | 10.1 | 72 | 12.1 | 29 | 180 | 0.28 | 500 m drum | 40393910094046 | |
19632910ZM | Enhanced Fire Safety Cable 4 x 1.5 | white | 1.5 | 10.1 | 72 | 12.1 | 29 | 180 | 0.28 | 200 m drum | 40393910094039 | |
19632910ZN | Enhanced Fire Safety Cable 4 x 1.5 | white | 1.5 | 10.1 | 72 | 12.1 | 29 | 180 | 0.28 | 100 m drum | 40393910094022 |
Technical specifications
Cable for fire alarm systems and emergency lighting for permanent installation in buildings.
Permitted operating temperature at conductor of +90˚C.
Minimum bending radius permanent (multi core) | 6 x D |
---|---|
Minimum bending during installation (multi core) | 6 x D |
Circuit integrity | PH 120 |
---|---|
Installation temperature | -5 °C - +50 °C |
Operating temperature | -40 °C - +90 °C |
Test voltage at 50Hz | 2000 |
---|---|
Nominal voltage | 300/500V |
Typical applications are: BS 5839-1 for enhanced fire resistant cables in fire detection and fire alarm systems for building BS 5839-8 for voice alarm systems BS 5839-9 for emergency voice communication systems BS 5266-1 for emergency ligthing of premises BS 8519 for fire-resistant control cable systems for life safety and fire-fighting application - Category 2 and 3 |
Additional dimensions available on request. |
Conductor | Plain annealed copper wire, solid class 1, EN 60228 |
---|---|
Insulation | Mica/Glass fire resistant tape. Fire resistant silicon rubber type EI2 to BS EN 50363-1 |
Core colours | HD 308 S2, BS 7629-1 |
Shielding | Aluminium/polyester tape and uninsulated tinned copper drain wire; IEC 60228, EN 60228 |
Outer sheath material | Polyolefin compound, BS 7655-6.1, LTS3 |
Circuit integrity | IEC 60331 (180 minutes), VDE 0472-814 (FE180), BS 6387 C/W/Z, IEC 60331-2 (120 minutes), VDE 0482-200 (PH120), BS EN 50200 (PH120) |
---|---|
Smoke density | IEC 61034-2, EN 61034-2, VDE 0482-1034-2 |
Zero halogen no corrosive gases | IEC 60754-1, EN 60754-1, VDE 0482-754-1 |
Flame propagation | IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2 |
Flame spread | IEC 60332-3-24, EN 60332-3-24, VDE 0482-332-3-24 |
LPCB Certificate | LPCB Certificate Number: 172h, Issue: 02 |
Documentation
-
BASEC Certificate
Download PDF [ 473.242 KB ]
-
Datasheet
Download PDF [ 138.773 KB ]
-
Datasheet
Download PDF [ 137.577 KB ]
-
Datasheet
Download PDF [ 138.416 KB ]
-
Datasheet
Download PDF [ 138.583 KB ]
-
Datasheet
Download PDF [ 138.139 KB ]
-
Datasheet
Download PDF [ 137.601 KB ]
-
LPCB Certificates
Download PDF [ 182.162 KB ]