FO Outdoor wbKT S-Micro BL / A-DQ(ZN)2Y, Fca

S-Micro, up to 576 fibres, Euroclass Fca
metal-free, non-armoured, longitudinally watertight

1 ≤ 12 fibres
2 Loose tube
3 Aramid yarn
4 Ripcord
5 HDPE sheath

04_Propagation- CPR_Fca 06_Density- 08_System- 05_Spread- 03_LS0H

Product variants & stock

Article No. Stock Number of used loose tubesFibres per loose tubeProductReaction to fireOuter sheath colourNumber of fibresFibre typeFibre categoryOuter sheath diameter [mm]Bending radius [mm]Weight [kg/km]Tensile load short term [N]Tensile load continuous [N]Crush resistance short term [N]Crush resistance continuous [N]Fire load [kWh/m]Packing unitGTIN / EAN
19172310FZ
212FO Outdoor wbKT S-Micro BL 2x12Fcablack24E9/125 G.657.A1OS25.31062550015016005000.2256by the metre40393910411560
19172410FZ
412FO Outdoor wbKT S-Micro BL 4x12Fcablack48E9/125 G.657.A1OS25.31062550015016005000.2264by the metre40393910411577
19172510FZ
812FO Outdoor wbKT S-Micro BL 8x12Fcablack96E9/125 G.657.A1OS26.11223550015016005000.3222by the metre40393910411584
19172610FZ
1212FO Outdoor wbKT S-Micro BL 12x12Fcablack144E9/125 G.657.A1OS27.815650100030016005000.5325by the metre40393910411591
19172710FZ
2412FO Outdoor wbKT S-Micro BL 24x12Fcablack288E9/125 G.657.A1OS29.318670100030016005000.6808by the metre40393910411607
19172810FZ
2424FO Outdoor wbKT S-Micro BL 24x24Fcablack576E9/125 G.657.A1OS213.0260120100030016005001.2544by the metre40393910411614

Technical specifications

Highly compact, metal-free fibre optic outdoor cable with with up to 576 fibres in stranded loose tubes and with dry interstices.
Easily cut-back, installation-friendly cable construction.
Tube colour(s) DIN (IEC 60304)
Armouring (rodent protection) non-armoured
Outer sheath material HDPE
Maximum number of fibres 576
Fibre diameter 250 µm
Standard delivery length [m] 6000 m
Installation temperature -5 °C - +50 °C
Storage temperature -25 °C - +70 °C
Operating temperature -25 °C - +70 °C
Imprint DATWYLER FO Outdoor wbKT S-Micro BL / A-DQ(ZN)2Y «No. of fibres» «Fibre type» «Batch no.» «Receiver wave receiver wave» «Meter marks»
Field of application Outdoor
Fibre colour code DIN (IEC 60304)
Datwyler recommends blowing in micro and mini cables in an ambient temperature range from -2°C to +35°C.
For installation, a blow-in device with a rubber pull-in bead is recommended.
FTTx, Fibre-to-the-home networks.
Optimised for injection into microducts.
Tensile performance IEC 60794-1-21 E1
Crush resistance IEC 60794-1-21 E3
Impact IEC 60794-1-21 E4
Repeated bending IEC 60794-1-21 E6
Torsion IEC 60794-1-21 E7
Kink IEC 60794-1-21 E10
Bend IEC 60794-1-21 E11
Temperature cycling IEC 60794-1-22 F1
Water penetration IEC 60794-1-22 F5
Reaction to fire EN 13501-6
Euroclass Fca
Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2

Documentation