CU 8202 4P

Data cable, S/FTP, Category 8.2, AWG22, Euroclass Dca
2000 MHz

1 Inner conductor: AWG22 Bare copper wire
2 PE insulated conductor: 1.6 mm
3 Screen (pair): Alu PETP foil
4 Overall screen: Tinned braided copper
5 Outer sheath: FRNC/LSOH Orange RAL 2003

04_Propagation CPR_Eca 10_Schielded_EN 06_Density 02_PoEp_rt 08_System- 05_Spread CPR_Dca 09_Oil- 03_LS0H 01_RoHS

Product variants & stock

Article No. Stock ProductReaction to fireDimensions n x p x [mm (AWG)]Outer sheath dimensions [mm]CU rate [kg/km]Weight [kg/km]Fire load [kWh/m]Packing unitGTIN / EAN
19204400DK
CU 8202 4PDca-s2,d1,a14 x 2 x 0.62 (AWG22)8.23669.20.211000 m drum40393910419849

Technical specifications

Electrically and mechanically excellent Cat.8.2 data cable with an extended frequency range up to 2000 MHz. Exceeds the requirements of ISO/IEC 11801, IEC 61156-9, IEC 61156-5, EN 50173-1, and EN 50288-12-1. Excellent shielding performance thanks to pair and braid shielding. Clear distinction of conductors in the connector due to colored longitudinal stripes. Compatible with all common connector systems according to EN 50173 and ISO/IEC 11801.
Minimum bending radius (during installation) 78 mm
Tensile strength (4P) 110 N
Minimum number of impacts 3
Minimal crush resistance / 10cm 1000 N
AWG 22
Solid / Flex Solid wire
Minimum bending radius (permanently installed) 39 mm
High-end data cable for data centres and structured building cabling.
For the transmission of digital and analog voice, image, multimedia, and data signals.
Suitable for all ICT network applications up to 40GBase-T (2000 MHz) up to 30 m (channel).
Up to Class FA (1000 MHz) up to 100 m according to EN 50173-1 and ISO/IEC 11801, as well as for multimedia applications.
Due to the increased conductor cross-section, it is ideal for Power over Ethernet (PoE), PoE+, and 4PPoE.
Category Cat.8.2
GBit/s Up to 40 Gbit/s (max. length 30m)
Loop resistance at 20 °C 119 Ω/km
Operating capacity 43 pF/m
Impedance at 100 MHz, ±5Ω 100 Ω
NVP % 75
Delay skew 17 ns/100 m
Shielding shielded
Near end unbalance attenuation LCL at 1-600 MHz 40 dB
Transfer impedance 1/10/30 MHz < 8/10/20 mΩ/m
Coupling attenuation 85 dB
Segregation class d
Installation temperature 0 °C - +50 °C
Operating temperature -20 °C - +60 °C
Wire colour white/blue-white, white/orange-white, white/green-white, white/brown-white (with length stripes)
Imprint DATWYLER «cable type» «additional text» «batch number» «meter marks»
Field of application Indoor
Reaction to fire EN 13501-6
Euroclass Dca
Smoke density IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2
Flame propagation IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
Flame spread IEC 60332-3-24, EN 60332-3-24
Cables standard ISO/IEC 61156-9, EN 50288-12-1, ISO/IEC 61156-5
Cat./Class Cat.8.2 / Class I/II
PoE IEEE 802.3bt Type 4 (100W)
Outer sheath material FRNC/LSZH
Outer sheath colour orange

Documentation