CU 7002 6x4P Breakout Light (BOL)
Data cable, S/FTP, Category 7, AWG23, Euroclass Dca
1000 MHz
1 Inner conductor: AWG23 Bare copper wire
2 PE insulated conductor: 1.4 mm Ø
3 Screen (pair): Alu PETP foil
4 Overall screen: Tinned braided copper
5 Single cable sheath: FRNC/LS0H orange RAL 2003
6 Outer foil of Breakout Light (BOL) construction:
Polyester foil, transparent, sealed











Product variants & stock
Download
Article No. | Stock | Product | Reaction to fire | Dimensions n x p x [mm (AWG)] | Outer sheath dimensions [mm] | CU rate [kg/km] | Weight [kg/km] | Fire load [kWh/m] | Packing unit | GTIN / EAN |
---|---|---|---|---|---|---|---|---|---|---|
18848600DZ | CU 7002 6x4P BOL | Dca-s2,d1,a1 | 6 x (4 x 2 x 0.57 (AWG23)) | 21.8 | 186.6 | 386 | 0.96 | by the metre | 40393910034516 |
Technical specifications
Electrically and mechanically superior quality Cat.7 data cable - exceeds the requirements of ISO/IEC 11801, IEC 61156-5, EN 50173-1 and EN 50288-4-1.
Excellent shielding effect due to individually screened pairs and overall copper braid.
Easy handling, small outer diameter and reduced weight thanks to the Breakout Light construction with outer polyester foil instead of an overall cable sheath.
Considerable shorter installation time due to the multi-cable construction.
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.
Excellent shielding effect due to individually screened pairs and overall copper braid.
Easy handling, small outer diameter and reduced weight thanks to the Breakout Light construction with outer polyester foil instead of an overall cable sheath.
Considerable shorter installation time due to the multi-cable construction.
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.
Tensile strength (4P) | 600 N |
---|---|
Minimum bending radius (during installation) | 170 mm |
Minimal crush resistance / 10cm | 1000 N |
Minimum number of impacts | 10 |
AWG | 23 |
Solid / Flex | Solid wire |
Minimum bending radius (permanently installed) | 85 mm |
Data cable for structured premises cabling. For the transmission of digital and analogue voice, video and data signals. Suitable for all applications up to class F applications (600 MHz) in accordance with EN 50173-1 and ISO/IEC 11801 and for the transmission of broadband signals (such as cable TV) in accordance with IEC 15018. Applicable for Power over Ethernet (PoE) / PoE+ and 4PPoE up to 100W. Especially suitable for Consolidation Points (e.g. in open-plan offices). |
Category | Cat.7 |
---|---|
GBit/s | Up to 10 Gbit/s |
Loop resistance at 20 °C | 140 Ω/km |
Operating capacity | 42 pF/m |
Impedance at 100 MHz, ±5Ω | 100 Ω |
NVP % | 81 |
Delay skew | 12 ns/100 m |
Shielding | shielded |
Near end unbalance attenuation LCL at 1-600 MHz | 40 dB |
Transfer impedance 1/10/30 MHz | < 6/6/10 mΩ/m |
Coupling attenuation | 85 dB |
Segregation class | d |
Installation temperature | 0 °C - +50 °C |
---|---|
Operating temperature | -20 °C - +60 °C |
Wire colour | white/blue, white/orange, white/green, white/brown, according to IEC 60189 and IEC 60708 |
Imprint | DATWYLER «cable type» «additional text» «batch number» «meter marks» |
Field of application | Indoor |
Reaction to fire | EN 13501-6 |
---|---|
Euroclass | Dca |
Smoke density | IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD |
Zero halogen no corrosive gases | IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA |
Flame propagation | IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2 |
Cables standard | ISO/IEC 61156-5, EN 50288-4-1 |
Cat./Class | Cat.7 / Class F |
PoE | IEEE 802.3bt Type 4 (100W) |
Outer sheath material | FRNC/LSZH |
---|---|
Outer sheath colour | orange |