CU 7002 4P / 2x4P F8

Data cable, S/FTP, Category 7, AWG23, Euroclass Cca
1000 MHz

1 Inner conductor: AWG23 Bare copper wire
2 PE insulated conductor: 1.4 Ø
3 Screen (pair): Alu PETP foil
4 Overall screen: Tinned braided copper
5 Outer sheath: FRNC/LSOH Orange RAL 2003

01_RoHS 04_Propagation 05_Spread 10_Schielded_EN 06_Density 08_System- 03_LS0H CPR_B2ca_sw CPR_Cca CPR_Dca CPR_Eca CPR_Fca Piktogramm_4PPoE_PL89m

Product variants & stock

Article No. Stock ProductReaction to fireDimensions n x p x [mm (AWG)]Outer sheath dimensions [mm]CU rate [kg/km]Weight [kg/km]Fire load [kWh/m]Packing unitGTIN / EAN
17738800CK
CU 7002 4PCca-s1a,d1,a14 x 2 x 0.57 (AWG23)7.031.150.90.1211000 m drum40393910043556
17739800CL
CU 7002 2x4PCca-s1a,d1,a12 x (4 x 2 x 0.57 (AWG23))7.2 x 15.462.2113.60.32500 m drum40393910043365

Technical specifications

Electrically and mechanically superior quality Cat.7 data cable - exceeds the requirements of ISO/IEC 11801, IEC 61156-5, EN 50173-1 and EN 50288-4-1.
Excellent shielding effect due to individually screened pairs and overall copper braid.
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.
Data cable for structured premises cabling. For the transmission of digital and analogue voice, video and data signals.
Suitable for all ICT network applications up to class F applications (600 MHz) in accordance with EN 50173-1 and ISO/IEC 11801 and for the transmission of broadband signals (such as cable TV) in accordance with IEC 15018.
Applicable for Power over Ethernet (PoE) / PoE+ and 4PPoE up to 100W.
AWG 23
Solid / Flex Solid wire
Minimum bending radius (permanently installed) 30 mm
Minimum bending radius (during installation) 60 mm
Tensile strength (2x4P) 220 N
Tensile strength (4P) 110 N
Minimum number of impacts 10
Minimal crush resistance / 10cm 1000 N
Category Cat.7
GBit/s Up to 10 Gbit/s
Loop resistance at 20 °C 140 Ω/km
Operating capacity 42 pF/m
Impedance at 100 MHz, ±5Ω 100 Ω
NVP % 81
Delay skew 12 ns/100 m
Shielding shielded
Near end unbalance attenuation LCL at 1-600 MHz 40 dB
Transfer impedance 1/10/30 MHz < 6/6/10 mΩ/m
Coupling attenuation 85 dB
Segregation class d
Installation temperature 0 °C - +50 °C
Operating temperature -20 °C - +60 °C
Wire colour white/blue, white/orange, white/green, white/brown, according to IEC 60189 and IEC 60708
Imprint DATWYLER «cable type» «additional text» «batch number» «meter marks»
Field of application Indoor
Reaction to fire EN 13501-6
Euroclass Cca
Smoke density IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Section 4.3.3 SD
Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Section 4.3.3 SA
Flame propagation IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Section 4.3.3 F1
Flame spread IEC 60332-3-24, EN 60332-3-24, AREI-RGIE Section 4.3.3 F2
Cables standard ISO/IEC 61156-5, EN 50288-4-1
Cat./Class Cat.7 / Class F
PoE IEEE 802.3bt Type 4 (100W)
Outer sheath material FRNC/LSZH
Outer sheath colour orange

Documentation