CU 7000 4P Home

Data cable, S/FTP, Category 7, AWG26, Euroclass Dca
1000 MHz

1 Inner conductor: AWG26 bare copper wire
2 Wire: 1.0mm ∅
3 Screen (pair): Alu PETP foil
4 Overall screen: Tinned braided copper
5 Outer sheath: FRNC/LS0H white RAL 9010

01_RoHS 04_Propagation 05_Spread 02_PoEp_rt 06_Density 08_System- 03_LS0H CPR_Dca CPR_Eca

Product variants & stock

Article No. Stock ProductReaction to fireDimensions n x p x [mm (AWG)]Outer sheath dimensions [mm]CU rate [kg/km]Weight [kg/km]Fire load [kWh/m]Packing unitGTIN / EAN
19199100DP
CU 7000 4PDca-s2,d1,a14 x 2 x 0.42 (AWG26)5.618350.11305 m PullQuick box40393910029031
19199100DK
CU 7000 4PDca-s2,d1,a14 x 2 x 0.42 (AWG26)5.618350.111000 m drum

Technical specifications

Electrically and mechanically high-quality Cat.7 data cable - exceeds the requirementsof ISO/IEC 11801, IEC 61156-5, EN 50173-1 and EN 50288-4-1 on links up to 60 metres.
Excellent shielding effect due to individually screened pairs and overall copper braid.
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.
Tensile strength (4P) 62 N
Minimum bending radius (during installation) 46 mm
Minimal crush resistance / 10cm 1000 N
Minimum number of impacts 3
AWG 26
Solid / Flex Solid wire
Minimum bending radius (permanently installed) 23 mm
Data cable for in-home network cabling and residential premise cabling with maximum link lengths of up to 60 metres.
For the transmission of digital and analogue voice, video and data signals.
Supports Ethernet protocols up to 10GBase-T and all Power over Ethernet applications.
10GBase-T is fully supported when installing up to three CU 7000 4P cables in the same M20 pipe and four CU 7000 4P cables in the same M25 pipe (Alien NEXT cancellation due to foil and braid shielding).
Suitable for all ICT network applications up to class F applications (600 MHz) in accordance with EN 50173-1 and ISO/IEC 11801 on links up to 60 m.
Category Cat.7
GBit/s Up to 10 Gbit/s
Loop resistance at 20 °C 260 Ω/km
Operating capacity 41 pF/m
Impedance at 100 MHz, ±5Ω 100 Ω
NVP % 81
Delay skew 12 ns/100 m
Shielding shielded
Near end unbalance attenuation LCL at 1-600 MHz 40 dB
Transfer impedance 1/10/30 MHz < 11/10/30/100 mΩ/m
Coupling attenuation 85 dB
Segregation class d
Installation temperature 0 °C - +50 °C
Operating temperature -20 °C - +60 °C
Wire colour white/blue, white/orange, white/green, white/brown, according to IEC 60189 and IEC 60708
Imprint DATWYLER «cable type» «additional text» «batch number» «meter marks»
Field of application Indoor
Reaction to fire EN 13501-6
Euroclass Dca
Smoke density IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2
Flame propagation IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
Flame spread IEC 60332-3-24, EN 60332-3-24
Cables standard ISO/IEC 61156-5, EN 50288-4-1
Cat./Class Cat.7 / Class F
PoE IEEE 802.3at
Outer sheath material FRNC/LSZH
Outer sheath colour white

Documentation