CU 6002 4P
Data cable, U/FTP, Category 6, AWG23, Euroclass Dca
300 MHz
1 Inner conductor: AWG23 Bare copper wire
2 PE insulated conductor: 1.3 mm Ø
3 Screen (pair): Alu PETP foil
4 Drain wire: Tinned copper wire
5 Outer sheath: FRNC/LS0H orange RAL 2003











Product variants & stock
Download
Article No. | Stock | Product | Reaction to fire | Dimensions n x p x [mm (AWG)] | Outer sheath dimensions [mm] | CU rate [kg/km] | Weight [kg/km] | Fire load [kWh/m] | Packing unit | GTIN / EAN |
---|---|---|---|---|---|---|---|---|---|---|
182936 | CU 6002 4P | Dca-s2,d1,a1 | 4 x 2 x 0.55 (AWG23) | 6.8 | 20.0 | 48 | 0.15 | 1000 m drum | 40393910077513 | |
18293600DK | CU 6002 4P | Dca-s2,d1,a1 | 4 x 2 x 0.55 (AWG23) | 6.8 | 20.0 | 48 | 0.15 | 1000 m drum | 40393910040197 | |
18293600DL | CU 6002 4P | Dca-s2,d1,a1 | 4 x 2 x 0.55 (AWG23) | 6.8 | 20.0 | 48 | 0.15 | 500 m drum | 40393910040180 |
Technical specifications
Electrically and mechanically advanced quality Cat.6 data cable - fulfils the requirements of ISO/IEC 11801, IEC 61156-5, EN 50173-1 and EN 50288-5-1.
Good shielding effect due to individually screened pairs.
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.
Good shielding effect due to individually screened pairs.
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.
Tensile strength (4P) | 95 N |
---|---|
Minimum bending radius (during installation) | 56 mm |
Minimal crush resistance / 10cm | 1000 N |
Minimum number of impacts | 10 |
AWG | 23 |
Solid / Flex | Solid wire |
Minimum bending radius (permanently installed) | 28 mm |
Data cable for structured premises cabling. For the transmission of digital and analogue voice, video and data signals. Suitable for all ICT network applications up to class E applications (250 MHz) in accordance with EN 50173-1 and ISO/IEC 11801. Applicable for Power over Ethernet (PoE) / PoE+. |
Category | Cat.6 |
---|---|
GBit/s | Up to 1 Gbit/s |
Loop resistance at 20 °C | 150 Ω/km |
Operating capacity | 42 pF/m |
Impedance at 100 MHz, ±5Ω | 100 Ω |
NVP % | 79 |
Delay skew | 5 ns/100 m |
Shielding | shielded |
Near end unbalance attenuation LCL at 1-600 MHz | 40 dB |
Transfer impedance 1/10/30 MHz | < 50/100/200 mΩ/m |
Coupling attenuation | 55 dB |
Segregation class | c |
Installation temperature | 0 °C - +50 °C |
---|---|
Operating temperature | -20 °C - +60 °C |
Wire colour | white/blue, white/orange, white/green, white/brown, according to IEC 60189 and IEC 60708 |
Imprint | DATWYLER «cable type» «additional text» «batch number» «meter marks» |
Field of application | Indoor |
Reaction to fire | EN 13501-6 |
---|---|
Euroclass | Dca |
Smoke density | IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD |
Zero halogen no corrosive gases | IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA |
Flame propagation | IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Art.104-F1 |
Cables standard | ISO/IEC 61156-5, EN 50288-5-1 |
Cat./Class | Cat.6 / Class E |
PoE | IEEE 802.3bt Type 4 (100W) |
Outer sheath material | FRNC/LSZH |
---|---|
Outer sheath colour | orange |