1 Inner conductor: AWG26, bare copper wire, stranded
2 PE insulated conductor: Ø 0.98 mm
3 Polyester foil
4 Overall screen: tinned braided copper
5 Outer sheath: FRNC/LS0H, various colours
Product variants & stock
Article No.
Stock
Product
Reaction to fire
Dimensions n x p x [mm² (AWG)]
Outer sheath colour
Outer sheath dimensions [mm]
CU rate [kg/km]
Weight [kg/km]
Fire load [kWh/m]
Packing unit
GTIN / EAN
18110002DK
CU 5502 4P Flex
Dca-s2,d2,a1
4 x 2 x 0.16 (AWG26)
orange
5.1
24
34
0.09
1000 m drum
40393910042511
18110302DK
CU 5502 4P Flex
Dca-s2,d2,a1
4 x 2 x 0.16 (AWG26)
yellow
5.1
24
34
0.09
1000 m drum
40393910042375
18110102DK
CU 5502 4P Flex
Dca-s2,d2,a1
4 x 2 x 0.16 (AWG26)
grey
5.1
24
34
0.09
1000 m drum
40393910042467
18110202DK
CU 5502 4P Flex
Dca-s2,d2,a1
4 x 2 x 0.16 (AWG26)
green
5.1
24
34
0.09
1000 m drum
40393910042412
18110402DK
CU 5502 4P Flex
Dca-s2,d2,a1
4 x 2 x 0.16 (AWG26)
red
5.1
24
34
0.09
1000 m drum
40393910042337
18110502DK
CU 5502 4P Flex
Dca-s2,d2,a1
4 x 2 x 0.16 (AWG26)
blue
5.1
24
34
0.09
1000 m drum
40393910042290
18110602DK
CU 5502 4P Flex
Dca-s2,d2,a1
4 x 2 x 0.16 (AWG26)
black
5.1
24
34
0.09
1000 m drum
40393910042252
18110702DK
CU 5502 4P Flex
Dca-s2,d2,a1
4 x 2 x 0.16 (AWG26)
purple
5.1
24
34
0.09
1000 m drum
40393910042214
18110802DK
CU 5502 4P Flex
Dca-s2,d2,a1
4 x 2 x 0.16 (AWG26)
white
5.1
24
34
0.09
1000 m drum
40393910042177
Technical specifications
Electrically and mechanically superior quality Cat.5e patch cord - exceeds the requirements of ISO/IEC 11801, IEC 61156-6, EN 50173-1 and EN 50288-2-2.
Construction optimised for fast and reliable terminations.
Easy wire identification and termination due to different coloured wires.
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.
Optimised for RJ45 connecting systems.
Differently coloured sheaths facilitate clearly arranged installations and visual differentiation of services.
AWG
26
Repeated bending
1000 cycles
Tensile strength (4P)
63
N
Minimal crush resistance / 10cm
1000
N
Minimum number of impacts
10
Solid / Flex
Stranded wire (flexible)
Minimum bending radius
20
mm
Segregation class
c
Category
Cat.5e
Loop resistance at 20 °C
220
Ω/km
Operating capacity
45
pF/m
Delay skew
15
ns/100 m
Impedance at 100 MHz, ±5Ω
100
Ω
Transfer impedance 1/10/30 MHz
< 20/9/25 mΩ/m
Near end unbalance attenuation LCL at 1-600 MHz
40
dB
NVP %
75
Coupling attenuation
55
dB
Minimum insulation resistance
5000
GBit/s
Up to 1 Gbit/s
Shielding
shielded
As patch cord in patch panels and as equipment connection cable.
For the transmission of digital and analogue voice, video and data signals.
Suitable for all ICT network applications up to class D applications (100 MHz) in accordance with EN 50173-1 and ISO/IEC 11801.
Applicable for Power over Ethernet (PoE) / PoE+.
Wire colour
white/blue, red/orange, black/green, yellow/brown, according to IEC 60189 and IEC 60708