Fire alarm cable with steel wire braiding, max. 225V, Keram
halogen-free, with improved fire characteristics,
with reference to VDE 0815,
circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331, EN 50200,
System Circuit Integrity E30-E90* in accordance with DIN 4102-12
JE-H(St)HRH...Bd FE180 E30-E90 fire alarm 2x2x0.8 mm
red
9.2
25
124
0.26
by the metre
40393910072921
188120
JE-H(St)HRH...Bd FE180 E30-E90 fire alarm 4x2x0.8 mm
red
12
45
191
0.39
by the metre
40393910072914
188127
JE-H(St)HRH...Bd FE180 E30-E90 fire alarm 8x2x0.8 mm
red
18.2
85
418
0.93
by the metre
40393910072877
188128
JE-H(St)HRH...Bd FE180 E30-E90 fire alarm 12x2x0.8 mm
red
19.1
126
489
1.01
by the metre
40393910072860
188129
JE-H(St)HRH...Bd FE180 E30-E90 fire alarm 20x2x0.8 mm
red
22.5
206
679
1.32
by the metre
40393910072853
188346
JE-H(St)HRH...Bd FE180 E30-E90 fire alarm 32x2x0.8 mm
red
26.7
326
911
1.72
by the metre
40393910072365
Technical specifications
Cables with intrinsic fire resistance are installed in all areas that require special protection of people and equipment against fire and fire damages and where strict security requirements must be fulfilled. Suitable for indoor applications. For outdoor applications, protection must be provided against exposure to direct sunlight. The steel wire braiding serves as mechanical protection. The fire alarm cables correspond to the demands of System Circuit Integrity E30-E90* in accordance with DIN 4102-12. System Circuit Integrity is guaranteed at an operating voltage up to 110V.
Permitted operating temperature at conductor of +70°C.
operating capacity, 1km @ 800Hz
120
Maximum loop resistance 0,8 mm
73.2
Test voltage 50Hz, core/screen
2000
Minimum insulation resistance
100
Capacitive coupling 0,8 mm, 100m @ 800Hz
200
Test voltage 50Hz, core/core
500
peak voltage
225
Minimum bending radius permanent (multi core)
7.5 x D
Minimum bending during installation (multi core)
7.5 x D
Minimal crush resistance / 10cm
1000
N
Circuit integrity (FE180)
FE 180
System circuit integrity
E90
Installation temperature
-5 °C - +50 °C
Operating temperature
-30 °C - +70 °C
System Circuit Integrity dependent on installation method.
Conductor
Bare copper, solid, 0.8 mm diameter, VDE 0815
Insulation
Fire-resistant, cross-linked, high-performance Keram special compound, EN 50290-2-36
Core colours
VDE 0815
Shielding
Al-laminated tape with copper drain wire Ø 0.8 mm
Inner sheath
Flame retardant polyolefin compound, VDE 0819-107, EN 50290-2-27 and VDE 0250-214 "HM2"
Armouring (rodent protection)
Galvanised steel wire braid
Outer sheath material
Flame retardant polyolefin compound VDE 0819-107, EN 50290-2-27 and VDE 0250-214 "HM 2"