(N)HXCH FE180 E30-E60

Safety cable, 0.6/1kV, Keram
halogen-free, with improved fire characteristics,
with reference to VDE 0266 and CENELEC HD 604 S1,
circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331,
System Circuit Integrity E30-E60* in accordance with DIN 4102-12

1 Conductor: solid/stranded
2 Fire barrier: high-peformance Keram compound
3 Insulation: cross-linked polymer, zero halogen
4 Filler: flame retardant, zero halogen
5 Concentric conductor: bare copper wire
6 Reinforcing helix: bare copper tape
7 Separator: plastic tape
8 Sheath: FRNC/LSZH

07_Circuit 04_Propagation 05_Spread 06_Density 08_System 03_LS0H

Product variants & stock

Article No. Stock ProductDiameter mm²Outer sheath diameter [mm]CU rate [kg/km]Weight [kg/km]Fire load [kWh/m]ConductorConstructionGTIN / EAN
187234
(N)HXCH FE180 E30-E60 2 x 6/66/6161824290.86solidLN40393910074161
186943
(N)HXCH FE180 E30-E60 2 x 1.5/1.51.5/1.512.7522210.60solidLN40393910075366
186944
(N)HXCH FE180 E30-E60 2 x 2.5/2.52.5/2.513.5802690.66solidLN40393910075359
187232
(N)HXCH FE180 E30-E60 2 x 4/44/414.91233510.78solidLN40393910074178
186945
(N)HXCH FE180 E30-E60 3 x 1.5/1.51.5/1.513.2662460.65solid3L40393910075342
186946
(N)HXCH FE180 E30-E60 3 x 2.5/2.52.5/2.514.11043030.72solid3L40393910075335
187238
(N)HXCH FE180 E30-E60 3 x 16/1616/1621.3624.710251.63stranded3L40393910074154
187239
(N)HXCH FE180 E30-E60 3 x 25/1625/162590214331.90stranded3L40393910074147
187240
(N)HXCH FE180 E30-E60 3 x 35/1635/1637.3119017992.20stranded3L40393910074130
187241
(N)HXCH FE180 E30-E60 3 x 50/2550/2531.7172324502.84stranded3L40393910074123
187242
(N)HXCH FE180 E30-E60 3 x 70/3570/3536241033413.52stranded3L40393910074116
186985
(N)HXCH FE180 E30-E60 3 x 95/5095/5041.1329644454.50stranded3L40393910074956
186986
(N)HXCH FE180 E30-E60 3 x 120/70120/7044.5423655245.30stranded3L40393910074949
186987
(N)HXCH FE180 E30-E60 3 x 150/70150/7049.2510067306.00stranded3L40393910074932
186988
(N)HXCH FE180 E30-E60 3 x 240/120240/12061.58242109089.93stranded3L40393910074925
186947
(N)HXCH FE180 E30-E60 4 x 1.5/1.51.5/1.514.1812810.73solid3LN40393910075328
186948
(N)HXCH FE180 E30-E60 4 x 2.5/2.52.5/2.515.11283500.82solid3LN40393910075311
186949
(N)HXCH FE180 E30-E60 4 x 4/44/416.72004640.96solid3LN40393910075304
186950
(N)HXCH FE180 E30-E60 4 x 6/66/618.12976131.13solid3LN40393910075298
186951
(N)HXCH FE180 E30-E60 4 x 10/1010/1020.15048581.33solid3LN40393910075281
186989
(N)HXCH FE180 E30-E60 4 x 16/1616/1623.479612471.70stranded3LN40393910074918
186990
(N)HXCH FE180 E30-E60 4 x 25/1625/1627.2114217422.20stranded3LN40393910074901
186991
(N)HXCH FE180 E30-E60 4 x 35/1635/1629.8152622002.56stranded3LN40393910074895
186992
(N)HXCH FE180 E30-E60 4 x 50/2550/2534.8220330293.41stranded3LN40393910074888
186993
(N)HXCH FE180 E30-E60 4 x 70/3570/3539.5308241284.18stranded3LN40393910074871
186994
(N)HXCH FE180 E30-E60 4 x 95/5095/5045.2420855035.58stranded3LN40393910074864
186995
(N)HXCH FE180 E30-E60 4 x 120/70120/7049.1538868626.37stranded3LN40393910074857
186996
(N)HXCH FE180 E30-E60 4 x 150/70150/7054.3654083997.83stranded3LN40393910074840
186997
(N)HXCH FE180 E30-E60 4 x 185/95185/9559.88159104709.55stranded3LN40393910074833
186998
(N)HXCH FE180 E30-E60 4 x 240/120240/12067.9105461360012.00stranded3LN40393910074826
187244
(N)HXCH FE180 E30-E60 7 x 1.5/2.51.5/2.516.11333900.94solid7L40393910074109
187245
(N)HXCH FE180 E30-E60 30 x 1.5/61.5/628.449912322.67solid30L40393910074093

Technical specifications

Cables with intrinsic fire resistance are installed in all areas that require special protection of people and equipment against fire and fire damages and where strict security requirements must be fulfilled. Suitable for indoor applications. For outdoor applications, protection must be provided against exposure to direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used. These cables correspond to the demands of System Circuit Integrity E30-E60* in accordance with DIN 4102-12. System Circuit Integrity is guaranteed at an operating voltage up to 400V. Permitted operating temperature at conductor of +90˚C.
Minimum bending radius permanent (multi core) 12 x D
Minimum bending during installation (single core) 15 x D
Minimum bending radius permanent (single core) 15 x D
Minimum bending during installation (multi core) 12 x D
Screened no
Circuit integrity (FE180) FE 180
System circuit integrity E30-E60*
Installation temperature -5 °C - +50 °C
Operating temperature -45 °C - +90 °C
Test voltage at 50Hz 4000
Nominal voltage 0.6/1kV
System Circuit Integrity is dependent on installation method.
Conductor Bare copper, solid or stranded, IEC 60228 and EN 60228 (VDE 0295)
Insulation Double insulation, cross-linked, high-performance Keram special compound, VDE 0266 "HXI1"
Core colours CENELEC HD 308 S2, VDE 0293
Separator Plastic tape
Filler Flame retardant, halogen-free thermoplastic compound
Concentric conductor Bare copper wires with reinforced helix
Outer sheath material Flame retardant Polyolefin compound, CENELEC HD 604 S1 and VDE 0276-604 "HM4"
Outer sheath colour orange
Circuit integrity (FE180) IEC 60331-11/-21 (180 minutes), VDE 0472-814 (FE180), BS 6387 C/W/Z, IEC 60331-1 (120 minutes), IEC 60331-2 (120 minutes), EN 50200 (PH120 minutes), VDE 0482-200 (PH120), AREI-RGIE Art.104-FR1
System circuit integrity DIN 4102-12, AREI-RGIE Art.104-FR2
Smoke density IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD
Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA
Flame propagation IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Art.104-F1
Flame spread IEC 60332-3-22/-24, EN 60332-3-22/-24, VDE 0482-332-3-22/-24, AREI-RGIE Art.104-F2

Documentation