SMDC – Multi-module
up to 300 kVA, hybrid cooling
Este producto no está disponible en su región.
Variantes de productos y existencias
Descargar
Artículo No. | Stock | Prodotto | IT load | Available space | Cooling / Condenser | Input power |
---|---|---|---|---|---|---|
41905003ZY | SMDC – Multi-module | up to 267 kW | up to 100 racks | In-row / outdoor | 380 - 415 VAC, 3Ph+N+PE 50/60Hz |
Especificaciones técnicas
The Smart Modular Data Centre (SMDC) is a scalable, pre-assembled, plug-and-play solution designed for edge computing and engineered for rapid deployment.
The multi-module SMDC ensures a capacity of up to 300 kVA. It consists of 42U racks, integrated intelligent power distribution, uninterruptible power supplies (UPS) and a flexible cooling system with a capacity of up to 25 kW per cooling unit.
It also includes a fire extinguishing system, air gap sealing and comprehensive software for infrastructure management.
This multi-module solution offers multiple configuration options for redundant power and cooling enabling seamless scalability and technology upgrades with little additional cost or disruption.
The multi-module SMDC ensures a capacity of up to 300 kVA. It consists of 42U racks, integrated intelligent power distribution, uninterruptible power supplies (UPS) and a flexible cooling system with a capacity of up to 25 kW per cooling unit.
It also includes a fire extinguishing system, air gap sealing and comprehensive software for infrastructure management.
This multi-module solution offers multiple configuration options for redundant power and cooling enabling seamless scalability and technology upgrades with little additional cost or disruption.
Impresión de aplicaciones |
The multi-module SMDC supports edge computing, operating smart facilities with IoT devices, and running remote or branch offices. Advanced applications include technologies such as AI, AR, VR and automation systems that require flexible, scalable and energy-efficient real-time data processing. |
---|
Ventilación de emergencia | Top of the rack and front door, extracting hot air from the rack in case of cooling failure |
---|---|
PDU | Intelligent power management |
Capacidad del SAI | up to 300 kVA |
Ampliación del tiempo de autonomía del SAI (opcional) | 8 to 15 minutes |
Interfaz de usuario | 10.4" touch screen and remote web interface |
Sensores | Cooling system, UPS, power usage effectiveness (PUE), iPDU*, IT load, access control*, temperature, humidity and alarm status |
Alarma y notificación | Sound and light alarm with SMS and email notification |
Control de acceso | Card or keypad |
Supresión de incendios | FM200-J / NOVEC 1230 rack mounted (2U)* |
Puerta de entrada | Puerta delantera con vidrio de seguridad templado de 5 mm. |
---|---|
Puerta trasera | La puerta sólida trasera en chapa de acero |
Paneles laterales | Desmontable, con perno de toma de tierra |
Panel superior | la entrada del cable es posible |
Panel inferior | la entrada del cable es posible |
Perfil de montaje | 2 pares de perfiles verticales de 19" (delante / detrás) |