FE180 flex
Control cable flex, 300/500V, Keram
halogen-free, with improved fire characteristics,
with reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5.H
1 Conductor: stranded
2 Fire barrier: high-performance Keram compound
3 Insulation: cross-linked polymer, zero halogen
4 Filler: flame retardant, zero halogen
5 Sheath: FRNC / LSZH






Variantes de productos y existencias
Descargar
Artículo No. | Stock | Prodotto | Número de núcleos | Diámetro [mm2] | Diámetro exterior de la vaina [mm] | Prop. CU [kg/km] | Peso [kg/km] | Carga de fuego [kWh/m] | Construcción | GTIN / EAN |
---|---|---|---|---|---|---|---|---|---|---|
188335 | FE180 flex 3 x 1.5 | 3 | 1.5 | 8.5 | 43 | 123 | 0.27 | LNPE | 40393910072419 | |
187554 | FE180 flex 5 x 1.5 | 5 | 1.5 | 10.3 | 72 | 182 | 0.40 | 3LNPE | 40393910073645 | |
187179 | FE180 flex 5 x 2.5 | 5 | 2.5 | 12.1 | 120 | 271 | 0.55 | 3LNPE | 40393910074505 | |
192367 | FE180 flex 7 x 1.5 | 7 | 1.5 | 11 | 101 | 222 | 0.44 | 6LPE | 40393910067620 | |
185228 | FE180 flex 8 x 1.5 | 8 | 1.5 | 12.4 | 115 | 273 | 0.56 | 6LNPE | 40393910077315 | |
191059 | FE180 flex 12 x 1.5 | 12 | 1.5 | 14 | 173 | 313 | 0.72 | 11LPE | 40393910070033 | |
191060 | FE180 flex 16 x 1.5 | 16 | 1.5 | 16 | 231 | 410 | 0.89 | 15LPE | 40393910070026 | |
191061 | FE180 flex 21 x 1.5 | 21 | 1.5 | 18 | 303 | 527 | 1.10 | 20LPE | 40393910070019 |
Especificaciones técnicas
Safety cables are installed in all areas that require special protection of people and equipment against fire and fire damages and where strict security requirements must be fulfilled.
Suitable for indoor applications. For outdoor applications, protection must be provided against exposure to direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
Permitted operating temperature at conductor of +90˚C.
Suitable for indoor applications. For outdoor applications, protection must be provided against exposure to direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
Permitted operating temperature at conductor of +90˚C.
Radio de flexión mínimo permanente (multinúcleo) | 4 x D |
---|---|
Mínimo de flexión durante la instalación (multinúcleo) | 6 x D |
Integridad del aislamiento | FE 180 |
---|---|
Temperatura de instalación | -5 °C - +50 °C |
Temperatura de funcionamiento | -45 °C - +90 °C |
Tensión de prueba a 50 Hz | 2000 |
---|---|
Tensión nominal | 300/500V |
Additional dimensions available on request. |
Conductor | Bare copper, stranded, IEC 60228 class 5, EN 60228 |
---|---|
Aislamiento | Special compound, HD 604 S1 part 5 H |
Colores principales | CENELEC HD 308 S2 |
Relleno | HD 604 S1 part 5 H |
Material exterior de la vaina | Compound, HD 604 S1 part 5 H |
Integridad de circuito | IEC 60331-11/-21 (180 minutes), VDE 0472-814 (FE180), BS 6387 C/W/Z, IEC 60331-1 (120 minutes), IEC 60331-2 (120 minutos), EN 50200 (PH120 minutes), VDE 0482-200 (PH120), AREI-RGIE Section 4.3.3 FR1 |
---|---|
Densidad de humo | EN 61034-1/-2, IEC 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Section 4.3.3 SD, SEV TP 20B/3C 3.4.3 |
Cero halógeno gases no corrosivos | EN 60754-1/-2, IEC 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Section 4.3.3 SA, SEV TPV11 |
Propagación de llamas | EN 60332-1-2, IEC 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Section 4.3.3 F1, SEV TP 20B/3C 3.4.1.1 |
Dispersión de llamas | EN 60332-3-24, IEC 60332-3-24, VDE 0482-332-3-24, AREI-RGIE Section 4.3.3 F2, SEV TP 20B/3C 3.4.1.3 |