FL –FRNC - without data elements
Baja elevación - altura de recorrido máximo 80m
Drawing according to article number 191110 ; Type 8511-F




Variantes de productos y existencias
Descargar
Artículo No. | Stock | Prodotto | Diseño de cables | Prop. CU [kg/km] | Peso [kg/km] | GTIN / EAN |
---|---|---|---|---|---|---|
191110 | 8511-F | 12 G 0.75 mm² | 87 | 259 | 40393910069716 | |
185125 | 8511-F | 18 G 0.75 mm² | 130 | 382 | 40393910077353 | |
191112 | 8511-F | 24 G 0.75 mm² | 173 | 511 | 40393910069693 |
Especificaciones técnicas
Cable de suspensión de ascensores de interior y panorámicos.
Acceleration | 0.8 m/s² |
---|---|
Maximum running speed | 4 m/s |
Maximum travelling height | 80 m |
Maximum free suspension | 45 m |
Recommended loop diameter | de acuerdo con la tabla, tolerancia -50/+100 mm |
Pair/quad | various colours or black with white numbers |
---|---|
Core | black, white numbered, G = with green-yellow core(s) |
Coax | negro |
Temperatura de funcionamiento | -15 °C - +70 °C |
Rated voltage Uo/U | de acuerdo con la tabla |
---|
Impresión de aplicaciones | Para cumplir con los procedimientos de instalación correctos, por favor, consulte el manual de instalación de Datwyler que está disponible por separado. |
---|
Core insulation | bajo riesgo de incendio |
---|---|
Core flexible | clase 5 |
Supporting members | ninguno |
Material exterior de la vaina | low fire hazard |
Color de la funda exterior | negro |
Estándar para cables flexibles de control de ascensores | EN 50214 |
---|