CU 7702 4P FRNC/GG/FRNC
Data cable, S/FTP, Category 7A, AWG22, Euroclass Cca
1300 MHz
1 Inner conductor: AWG23 Bare copper wire
2 PE insulated conductor: 1.52 mm Ø
3 Screen (pair): Alu PETP foil
4 Overall screen: Tinned braided copper
5 Sheath: FRNC/LS0H orange RAL 2003
6 Rodent protection: with glass rovings
7 Ripcord
8 Outer sheath: FRNC/LS0H black










Varianti di prodotto e stock
Scaricare
Articolo n. | Stock | Prodotto | Reaction to fire | Dimensions n x p x [mm (AWG)] | Dimensioni della guaina esterna [mm] | Tasso di CU [kg/km] | Weight [kg/km] | Fire load [kWh/m] | Unità di imballaggio | GTIN / EAN |
---|---|---|---|---|---|---|---|---|---|---|
19435400CZ | CU 7702 4P | Cca-s1a,d1,a1 | 4 x 2 x 0.62 (AWG22) | 12.0 | 34.9 | 166.6 | 0.55 | al metro | 40393910022704 |
Specifiche tecniche
Applicable for outdoor installation due to rodent protection and UV resistant outer cable sheath.
Robust cable design with a high mechanical stability.
Electrically and mechanically superior quality Cat.7A data cable - exceeds the requirements of ISO/IEC 11801-1, IEC 61156-5, EN 50173-1 and EN 50288-9-1.
Excellent shielding effect due to individually screened pairs and overall copper braid.
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801-1.
Robust cable design with a high mechanical stability.
Electrically and mechanically superior quality Cat.7A data cable - exceeds the requirements of ISO/IEC 11801-1, IEC 61156-5, EN 50173-1 and EN 50288-9-1.
Excellent shielding effect due to individually screened pairs and overall copper braid.
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801-1.
Curvatura minima (durante l'installazione) | 96 mm |
---|---|
Resistenza alla trazione (4P) | 150 N |
Minimum number of impacts | 10 |
Resistenza minima allo schiacciamento / 10cm | 1000 N |
AWG | 22 |
Solid / Flex | stabile |
Raggio di curvatura minimo (installato in modo permanente) | 48 mm |
Data cable for structured premise cabling with enhanced mechanical and fire protection performance. Designed for installation in Tunnels, Metro-Systems and Buildings with augmented requirements. With rodent protection and UV protected outer sheath. Installation in ducts, tubes and on cable support systems. Suitable for all ICT network applications up to class FA applications (1000 MHz) in accordance with EN 50173-1 and ISO/IEC 11801. Supports 10Base-T, 100Base-T, 1GBase-T (1000Base-T) and 10GBase-T. Applicable for Power over Ethernet PoE / PoE+ / 4PPoE. |
Categoria | Cat.7A |
---|---|
GBit/s | A 10 Gbit/s |
Loop resistance at 20 °C | 116 Ω/km |
Operating capacity | 43 pF/m |
Impedenza a 100 MHz, ±5Ω | 100 Ω |
NVP % | 76 |
Ritardo Skew | 15 ns/100 m |
Schermatura | schermati |
Near end unbalance attenuation LCL at 1-600 MHz | 40 dB |
Transfer impedance 1/10/30 MHz | < 5/5/8 mΩ/m |
Attenuazione di accoppiamento | 85 dB |
Segregation class | d |
Installation temperature | 0 °C - +50 °C |
---|---|
Operating temperature | -20 °C - +60 °C |
Colore del filo | bianco/blu-bianco, bianco/arancio-bianco, bianco/verde-bianco, bianco/marrone-bianco (con strisce longitudinali) |
Impronta | DATWYLER «cable type» «additional text» «batch number» «meter marks» |
Campo di applicazione | All'aperto |
Reaction to fire | EN 13501-6 |
---|---|
Euroclass | Cca |
Densità del fumo | IEC 61034-1/-2, EN 61034-1/-2 |
Zero alogeni nessun gas corrosivo | IEC 60754-1/-2, EN 60754-1/-2 |
Propagazione della fiamma | EN 60332-1-2, IEC 60332-1-2, VDE 0482-332-1-2 |
Standard dei cavi | ISO/IEC 61156-5, EN 50288-9-1 |
Cat./Class | Cat.7A / Class FA |
PoE | IEEE 802.3bt Type 4 (100W) |
Materiale della guaina esterna | FRNC/LSZH |
---|---|
Colore della guaina esterna | nero |