CU 7060 4P Outdoor

Data cable, S/FTP, Category 6A, AWG23, Euroclass Fca
650 MHz

1 Inner conductor: AWG23 Bare copper wire
2 PE insulated conductor: 1.3 mm Ø
3 Screen (pair): Alu PETP foil
4 Overall screen: Tinned braided copper
5 Outer sheath: PE black

01_RoHS 04_Propagation- 05_Spread- 02_PoEp_gn 10_Schielded_EN 06_Density 08_System- 03_LS0H CPR_Dca_sw CPR_Eca_sw CPR_Fca

Varianti di prodotto e stock

Articolo n. Stock ProdottoReaction to fireDimensions n x p x [mm (AWG)]Dimensioni della guaina esterna [mm]Tasso di CU [kg/km]Weight [kg/km]Unità di imballaggioGTIN / EAN
19429500FK
CU 7060 4PFca4 x 2 x 0.55 (AWG23)7.326.4471000 m tamburo40393910024043
19429500FL
CU 7060 4PFca4 x 2 x 0.55 (AWG23)7.326.447500 m tamburo40393910024036

Specifiche tecniche

Electrically and mechanically superior quality Cat.6A data cable - exceeds the requirements of ISO/IEC 11801, IEC 61156-5, EN 50173-1 and prEN 50288-10-1.
Excellent shielding effect due to individually screened pairs and overall copper braid.
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.
Resistenza alla trazione (4P) 95 N
Curvatura minima (durante l'installazione) 65 mm
Resistenza minima allo schiacciamento / 10cm 1000 N
Minimum number of impacts 10
AWG 23
Solid / Flex stabile
Raggio di curvatura minimo (installato in modo permanente) 30 mm
Data cable for outdoor installation.
For the transmission of digital and analogue voice, video and data signals.
Suitable for all ICT network applications up to class EA applications (500 MHz) in accordance with EN 50173-1 and ISO/IEC 11801.
Applicable for Power over Ethernet (PoE) / PoE+.
Categoria Cat.6A
GBit/s A 10 Gbit/s
Loop resistance at 20 °C 146 Ω/km
Operating capacity 42 pF/m
Impedenza a 100 MHz, ±5Ω 100 Ω
NVP % 80
Ritardo Skew 4 ns/100 m
Schermatura schermati
Near end unbalance attenuation LCL at 1-600 MHz 40 dB
Transfer impedance 1/10/30 MHz < 6/10/20 mΩ/m
Attenuazione di accoppiamento 75 dB
Segregation class c
Installation temperature 0 °C - +50 °C
Operating temperature -20 °C - +60 °C
Colore del filo bianco/blu, bianco/arancio, bianco/verde, bianco/marrone, in conformità alle norme IEC 60189 e IEC 60708
Impronta DATWYLER «cable type» «additional text» «batch number» «meter marks»
Campo di applicazione Outdoor
Reaction to fire EN 13501-6
Euroclass Fca
Densità del fumo IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD
Zero alogeni nessun gas corrosivo IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA
Standard dei cavi ISO/IEC 61156-5, EN 50288-10-1
Cat./Class Cat.6A / Class EA
PoE IEEE 802.3bt Type 4 (100W)
Materiale della guaina esterna PE
Colore della guaina esterna nero

Documentazione