Multimode fibre, G50/125/250, OM3

bend optimized
IEC 60793-2-10 Type A1-OM3b, ISO/IEC 11801:2017 OM3, EN 50173:2018 OM3, TIA/EIA 492AAAC-B

1 Core
2 Cladding
3 Coating

Specifiche tecniche

Bend insensitive fibre with enhanced macrobending features, particularly recommended for high-performance transmissions in the 850 nm wavelength like 10-GbE with duplex links or 40/100-GbE with high-speed parallel optic links. The geometrical, optical and mechanical specifications meet or exceed all relevant international standards. This fibre is compatible with standard category OM2 fibres in existing/legacy networks.
Coating diameter [µm] 240 +/- 5
Maximum cladding/Coating concentricity error [µm] 12 µm
Test load [kpsi] 100 kpsi
Core diameter [µm] 50.0 +/- 2.5
Cladding diameter [µm] 125.0 +/- 1.0
Maximum core/cladding concentricity error [µm] 1.5 µm
Maximum cladding non-circularity[%] 1.2 %
In Premises cabling for LAN backbones (Campus and Vertical/Riser cabling), Fibre to the Office and Fibre to the Desk (FTTO, FTTD = horizontal cabling) as well as in Data Centre cabling.
Fiber specifications IEC 60793-2-10 Type A1-OM3b, ITU-T G.651.1, TIA/EIA 492AAAC-B
Cabling standards ISO/IEC 11801-1, EN 50173-1

Documentazione