FO Universal DLTS ZGGFR / U-BQ(ZN)BH, B2ca

up to 24 fibres, FRNC/LSZH sheath, Euroclass B2ca
senza metallo, interstizi asciutti, tubo sciolto senza gel,
protezione dai roditori, ignifugo, a tenuta d'acqua longitudinale

1 ≤ 24 fibres
2 Loose tube
3 Glass armour
4 Ripcord
5 FR/LS0H sheath

04_Propagation 05_Spread 06_Density 08_System- 03_LS0H CPR_B2ca CPR_Cca CPR_Dca CPR_Eca

Varianti di prodotto e stock

Articolo n. Stock Loose tube constructionFibres per loose tubeNumber of used loose tubesProdottoReaction to fireColore della guaina esternaNumero di fibreFibre typeCategoria di fibraDiametro esterno della guaina [mm]Raggio di curvatura [mm]Tasso di CU [kg/km]Weight [kg/km]Tensile load short term [N]Tensile load continuous [N]Crush resistance short term [N]Crush resistance continuous [N]Fire load [kWh/m]Unità di imballaggioGTIN / EAN
19708500BZ
141FO Universal DLTS 1x4B2ca-s1a,d1,a1heather violet4G50/125 OM4OM47.611506830001000500010000.234al metro40393910016833
19706600BZ
141FO Universal DLTS ZGGFR 1x4B2ca-s1a,d1,a1giallo4E9/125 G.652.D BLOOS27.611506830001000500010000.234al metro40393910017137
19708000BZ
141FO Universal DLTS 1x4B2ca-s1a,d1,a1turchese4G50/125 OM3OM37.611506830001000500010000.234al metro40393910016987
19706700BZ
161FO Universal DLTS ZGGFR 1x6B2ca-s1a,d1,a1giallo6E9/125 G.652.D BLOOS27.611506830001000500010000.234al metro40393910017106
19708100BZ
161FO Universal DLTS 1x6B2ca-s1a,d1,a1turchese6G50/125 OM3OM37.611506830001000500010000.234al metro40393910016956
19708600BZ
161FO Universal DLTS 1x6B2ca-s1a,d1,a1heather violet6G50/125 OM4OM47.611506830001000500010000.234al metro40393910016802
19706800BZ
181FO Universal DLTS ZGGFR 1x8B2ca-s1a,d1,a1giallo8E9/125 G.652.D BLOOS27.611506830001000500010000.234al metro40393910017076
19708200BZ
181FO Universal DLTS 1x8B2ca-s1a,d1,a1turchese8G50/125 OM3OM37.611506830001000500010000.234al metro40393910016925
19708700BZ
181FO Universal DLTS 1x8B2ca-s1a,d1,a1heather violet8G50/125 OM4OM47.611506830001000500010000.234al metro40393910016772
19618100BZ
1121FO Universal DLTS ZGGFR 1x12B2ca-s1a,d1,a1giallo12E9/125 G.652.D BLOOS27.6115067.730001000500010000.234al metro40393910019063
19708300BZ
1121FO Universal DLTS 1x12B2ca-s1a,d1,a1turchese12G50/125 OM3OM37.611506830001000500010000.234al metro40393910016895
19618500BZ
1121FO Universal DLTS 1x12B2ca-s1a,d1,a1heather violet12G50/125 OM4OM47.611506830001000500010000.234al metro40393910018905
19706400BZ
1121FO Universal DLTS 1x12B2ca-s1a,d1,a1lime green12G50/125 OM5OM57.611506830001000500010000.234al metro40393910017168
19618200BZ
1241FO Universal DLTS ZGGFR 1x24B2ca-s1a,d1,a1giallo24E9/125 G.652.D BLOOS28.212507835001500500010000.325al metro40393910019018
19708400BZ
1241FO Universal DLTS 1x24B2ca-s1a,d1,a1turchese24G50/125 OM3OM38.212507835001500500010000.325al metro40393910016864
19618600BZ
1241FO Universal DLTS 1x24B2ca-s1a,d1,a1heather violet24G50/125 OM4OM48.212507835001500500010000.325al metro40393910018851
19706500BZ
1241FO Universal DLTS 1x24B2ca-s1a,d1,a1lime green24G50/125 OM5OM58.212507835001500500010000.325al metro40393910210736

Specifiche tecniche

Robust, non-metallic fibre optic outdoor and indoor cable with one central dry loose tube. High crush resistance for high transmission reliability. Easy to handle due to cable construction with dry interstices and gel-free loose tubes. Longitudinal water-tightness by swelling yarn. Non-metallic rodent protection. The two coloured ripcords are easy to identify and enable the safe opening of the cable sheath. Flame retardant halogen-free FR/LS0H sheath.
Massimo numero di fibre 24
Lunghezza di consegna standard [m] 8000 m
Campo di applicazione Universale
Installation temperature -10 °C - +50 °C
Storage temperature -25 °C - +70 °C
Operating temperature -25 °C - +70 °C
Impronta DATWYLER FO Universal DLTS ZGGFR / U-BQ(ZN)BH «No. of fibres» «Fibre type» «Batch no.» MADE IN SWITZERLAND «Receiver wave receiver wave» «Meter marks»
Fibre colour code IEC 60304
LAN backbone, access and riser zone.
Connection cable between the building distributors and/or floor distributors.
Suitable for laying in cable trays, ducts and vertical shafts.
Can also be spliced in all FO distributors and joints.
Tensile performance IEC 60794-1-21 E1
Crush resistance IEC 60794-1-21 E3
Impact IEC 60794-1-21 E4
Repeated bending IEC 60794-1-21 E6
Torsion IEC 60794-1-21 E7
Kink IEC 60794-1-21 E10
Bend IEC 60794-1-21 E11
Variazione di temperatura IEC 60794-1-22 F1
Water penetration IEC 60794-1-22 F5
Reaction to fire EN 13501-6
Euroclass B2ca
Densità del fumo IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
Zero alogeni nessun gas corrosivo IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2
Propagazione della fiamma EN 60332-1-2, IEC 60332-1-2, VDE 0482-332-1-2
Flame spread IEC 60332-3-24
Resistenza ai raggi UV EN 50289-4-17
Materiale della guaina esterna FRNC/LSZH

Documentazione