(N)HXCH FE180 E90

Safety cable, 0.6/1kV, Keram
halogen-free, with improved fire characteristics,
with reference to VDE 0266 and CENELEC HD 604 S1,
circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331,
System Circuit Integrity E90 in accordance with DIN 4102-12

1 Conductor: solid/stranded
2 Fire barrier: high-peformance Keram compound
3 Insulation: cross-linked polymer, zero halogen
4 Filler: flame retardant, zero halogen
5 Concentric conductor: bare copper wire
6 Reinforcing helix: bare copper tape
7 Separator: plastic tape
8 Sheath: FRNC/LSZH

07_Circuit 04_Propagation 05_Spread 06_Density 08_System 03_LS0H

Varianti di prodotto e stock

Articolo n. Stock ProdottoDiametro mm²Diametro esterno della guaina [mm]Tasso di CU [kg/km]Weight [kg/km]Fire load [kWh/m]ConductorConstructionGTIN / EAN
187409
(N)HXCH FE180 E90 3 x 70/3570/3537.6241035363.42stranded3L40393910073775
186071
(N)HXCH FE180 E90 3 x 1.5/1.51.5/1.513.2662450.65solid3L40393910076813
186195
(N)HXCH FE180 E90 3 x 2.5/2.52.5/2.514.11043030.72solid3L40393910076257
186197
(N)HXCH FE180 E90 3 x 4/44/415.61614000.84solid3L40393910076233
187278
(N)HXCH FE180 E90 3 x 6/66/616.92405210.94solid3L40393910074048
187279
(N)HXCH FE180 E90 3 x 10/1010/1018.64087271.15solid3L40393910074031
172417
(N)HXCH FE180 E90 3 x 35/1635/1629119019442.25stranded3L40393910078657
187408
(N)HXCH FE180 E90 3 x 50/2550/2532.5172325492.90stranded3L40393910073782
187410
(N)HXCH FE180 E90 3 x 95/5095/5041.9329645814.50stranded3L40393910073768
187411
(N)HXCH FE180 E90 3 x 120/70120/7045.3423656885.02stranded3L40393910073751
187412
(N)HXCH FE180 E90 3 x 150/70150/7050510069126.00stranded3L40393910073744
187414
(N)HXCH FE180 E90 3 x 240/120240/12062.48242111539.08stranded3L40393910073737
186072
(N)HXCH FE180 E90 4 x 1.5/1.51.5/1.514.1812800.73solid3LN40393910076806
186196
(N)HXCH FE180 E90 4 x 2.5/2.52.5/2.515.11283500.82solid3LN40393910076240
186198
(N)HXCH FE180 E90 4 x 4/44/416.72004640.96solid3LN40393910076226
186199
(N)HXCH FE180 E90 4 x 6/66/618.12976151.13solid3LN40393910076219
186200
(N)HXCH FE180 E90 4 x 10/1010/1020.15048581.33solid3LN40393910076202
186131
(N)HXCH FE180 E90 4 x 16/1616/1625.379613981.81stranded3LN40393910076783
186132
(N)HXCH FE180 E90 4 x 25/1625/1628.9114218982.28stranded3LN40393910076776
186133
(N)HXCH FE180 E90 4 x 35/1635/1631.6152623822.60stranded3LN40393910076769
186134
(N)HXCH FE180 E90 4 x 50/2550/2536.7220332493.49stranded3LN40393910076752
186135
(N)HXCH FE180 E90 4 x 70/3570/3541.3308243704.25stranded3LN40393910076745
186136
(N)HXCH FE180 E90 4 x 95/5095/5046.4420857125.53stranded3LN40393910076738
186137
(N)HXCH FE180 E90 4 x 120/70120/7050.1538870786.25stranded3LN40393910076721
186138
(N)HXCH FE180 E90 4 x 150/70150/7055.3654086317.58stranded3LN40393910076714
186139
(N)HXCH FE180 E90 4 x 185/95185/9560.88159107279.18stranded3LN40393910076707
186140
(N)HXCH FE180 E90 4 x 240/120240/12069.2105461394711.60stranded3LN40393910076691
186073
(N)HXCH FE180 E90 7 x 1.5/2.51.5/2.516.11333900.94solid7L40393910076790
191096
(N)HXCH FE180 E90 7 x 2.5/2.52.5/2.517.32004851.05solid7L40393910069792
187415
(N)HXCH FE180 E90 12 x 1.5/2.51.5/2.520.2205.85891.38solid12L40393910073720
187402
(N)HXCH FE180 E90 24 x 1.5/61.5/62741310662.32solid24L40393910073812
187403
(N)HXCH FE180 E90 24 x 2.5/102.5/1029.669614192.69solid24L40393910073805
187404
(N)HXCH FE180 E90 30 x 1.5/61.5/628.449912322.67solid30L40393910073799
196386
(N)HXCH FE180 E90 3 x 16/1616/1624.464312061.64stranded3L40393910061109

Specifiche tecniche

Cables with intrinsic fire resistance are installed in all areas that require special protection of people and equipment against fire and fire damages and where strict security requirements must be fulfilled. Suitable for indoor applications. For outdoor applications, protection must be provided against exposure to direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used. These cables correspond to the demands of System Circuit Integrity E90* in accordance with DIN 4102-12. System Circuit Integrity is guaranteed at an operating voltage up to 400V. Permitted operating temperature at conductor of +90˚C.
Minimum bending radius permanent (multi core) 12 x D
Curvatura minima durante l'installazione (multicore) 12 x D
Integrità dell'isolamento FE 180
Integrità del circuito E90
Installation temperature -5 °C - +50 °C
Operating temperature -45 °C - +90 °C
Tensione di prova a 50Hz 4000
Nominal voltage 0.6/1kV
System Circuit Integrity is dependent on installation method.
Conduttore Bare copper, solid or stranded, IEC 60228 and EN 60228 (VDE 0295)
Isolamento Double insulation, cross-linked, high-performance Keram special compound, VDE 0266 "HXI1"
Colori delle anime CENELEC HD 308 S2, VDE 0293
Separator Plastic tape
Riempitrice Halogen-free compound or plastic tape
Conduttore concentrico Bare copper wires with reinforced helix
Materiale della guaina esterna Flame retardant Polyolefin compound, CENELEC HD 604 S1 and VDE 0276-604 "HM4"
Colore della guaina esterna arancia
Integrità del circuito (FE180) IEC 60331-11/-21 (180 minutes), VDE 0472-814 (FE180), BS 6387 C/W/Z, IEC 60331-1 (120 minutes), IEC 60331-2 (120 minutes), EN 50200 (PH120 minutes), VDE 0482-200 (PH120), AREI-RGIE Art.104-FR1
Integrità del circuito di sistema DIN 4102-12, VdS 3423 (più di 16,0 mm²), AREI-RGIE Art.104-FR2
Densità del fumo IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD
Zero alogeni nessun gas corrosivo IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA
Propagazione della fiamma AREI-RGIE Art.104-F1, EN 60332-1-2, IEC 60332-1-2, VDE 0482-332-1-2
Flame spread IEC 60332-3-22/-24, EN 60332-3-22/-24, VDE 0482-332-3-22/-24, AREI-RGIE Art.104-F2

Documentazione