FE5-CL

Safety cable, 0.6/1kV, armoured with rodent protection, euroclass B2ca
halogen-free, with improved fire characteristics,
with reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5. H

1 Conductor: solid/stranded
2 Insulation: cross-linked PE, zero halogen
3 Inner sheath: Polyolefin, flame retardant, zero halogen
4 Armouring: galvanised steel tape
5 Sheath: FRNC/LSZH

07_Circuit- 04_Propagation 05_Spread 06_Density 08_System- 03_LS0H CPR_B2ca CPR_Cca CPR_Dca CPR_Eca CPR_Fca

Varianti di prodotto e stock

Articolo n. Stock ProdottoReaction to fireDiametro mm²Diametro esterno della guaina [mm]Tasso di CU [kg/km]Weight [kg/km]Fire load [kWh/m]ConductorConstructionUnità di imballaggioGTIN / EAN
18838900BZ
FE5-CL-J 5 x 10B2ca-s1a,d1,a110184807321.56solid3LNPEal metro40393910035162
19040100BZ
FE5-CL-J 5 x 16B2ca-s1a,d1,a1162476811202.03stranded3LNPEal metro40393910032888
18092900BZ
FE5-CL-J 7 x 6B2ca-s1a,d1,a16174036241.1solid6LPEal metro40393910042597
18453100BZ
FE5-CL-J 7 x 10B2ca-s1a,d1,a110206729501.48solid6LPEal metro40393910040128
19059500BZ
FE5-CL-J 5 x 6B2ca-s1a,d1,a16162884900.92solid3LNPEal metro40393910032604
19103600BZ
FE5-CL-J 5 x 50B2ca-s1a,d1,a15036240031444.74stranded3LNPEal metro40393910032079
19106300BZ
FE5-CL-J 5 x 25B2ca-s1a,d1,a12528120017102.76stranded3LNPEal metro40393910031997
19106400BZ
FE5-CL-J 5 x 2.5B2ca-s1a,d1,a12.5121202600.59solid3LNPEal metro40393910031942
19109000BZ
FE5-CL-J 5 x 35B2ca-s1a,d1,a13531.8168022773.44stranded3LNPEal metro40393910031867
19156800BZ
FE5-CL-J 3 x 10B2ca-s1a,d1,a110162884990.91solidLNPEal metro40393910030372
19160000BZ
FE5-CL-J 5 x 95B2ca-s1a,d1,a19549456058548.16stranded3LNPEal metro40393910030280
19273000BZ
FE5-CL-J 3 x 2.5B2ca-s1a,d1,a12.510721680.41solidLNPEal metro40393910026900
19273100BZ
FE5-CL-J 5 x 4B2ca-s1a,d1,a14141923640.73solid3LNPEal metro40393910026870
19626800BZ
FE5-CL-J 3 x 1.5B2ca-s1a,d1,a11.59431180.3solidLNPEal metro40393910018424
19626400BZ
FE5-CL-J 5 x 1.5B2ca-s1a,d1,a11.510721750.45solid3LNPEal metro40393910018455
19109100BZ
FE5-CL-J 3 x 4B2ca-s1a,d1,a14111152380.48solidLNPEal metro40393910031812
19164500BZ
FE5-CL-J 3 x 6B2ca-s1a,d1,a16131733290.65solidLNPEal metro40393910030181
19586400BZ
FE5-CL-O 2 x 2.5B2ca-s1a,d1,a12.510491510.37solidLNal metro40393910021134
19167200BZ
FE5-CL-J 4 x 1.5B2ca-s1a,d1,a11.59581510.36solid3LPEal metro40393910030037

Specifiche tecniche

For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or concrete. Also suitable for outdoor applications. The cable should only be laid directly in earth or water if a protective conduit is used. Permitted operating temperature at conductor of +90˚C.
Minimum bending radius permanent (multi core) 12 x D
Curvatura minima durante l'installazione (anima singola) 15 x D
Minimum bending radius permanent (single core) 15 x D
Curvatura minima durante l'installazione (multicore) 12 x D
Integrità dell'isolamento No
Integrità del circuito No
Installation temperature -5 °C - +50 °C
Operating temperature -45 °C - +90 °C
Additional dimensions available on request.
Conduttore Bare copper, solid or stranded in accordance with IEC 60228 and EN 60228
Isolamento Cross-linked Polyethylene CENELEC HD 604 S1 part 5 sec. H
Colori delle anime CENELEC HD 308 S2
Armatura (protezione per roditori) Single-core cable with copper tape (CLCU) and multicore cable with galvanised steel tape (CL)
Materiale della guaina esterna Flame retardant Polyolefin compound CENELEC HD 604 S1 part 5 sec. H
Reaction to fire EN 13501-6
Euroclass B2ca
Densità del fumo IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD
Zero alogeni nessun gas corrosivo IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA
Propagazione della fiamma AREI-RGIE Art.104-F1, EN 60332-1-2, IEC 60332-1-2, VDE 0482-332-1-2
Flame spread IEC 60332-3-24, EN 60332-3-24, AREI-RGIE Art.104-F2

Documentazione