FL – FRNC

Low rise - travelling height maximum 80m

Drawing according to article number 182205; Type 8827-F

04_Propagation 05_Spread- 06_Density 03_LS0H

Varianti di prodotto e stock

Articolo n. Stock ProdottoDesign del cavoTasso di CU [kg/km]Weight [kg/km]GTIN / EAN
191111
8636-F12 G 0.75 + 3 x 2 x 0.50 mm² (FTP)12342040393910069709
182205
8827-F3 G 2.50 + 14 x 1.00 + 4 x 2 x 0.34 mm² (FTP)24473540393910077766
191113
8582-F24 G 1.00 + 3 x 2 x 0.75 mm² (FTP) + 1 CX 75 Ω30695840393910069686
190491
8582-F2 x 1.50 + 8 x 2 x 0.50 mm² (FTP) + 1 CX 75 Ω14952440393910070873

Specifiche tecniche

Elevator suspension cable for indoor and panoramic elevators.
Acceleration 0.8 m/s²
Maximum running speed 4 m/s
Maximum travelling height 80 m
Maximum free suspension 45 m
Recommended loop diameter according to table, tolerance -50/+100 mm
Coppia / quartetto various colours or black with white numbers
Anima black, white numbered, G = with green-yellow core(s)
Coassiale nero
Temperatura di esercizio -15 °C - +70 °C
Rated voltage Uo/U according to table
To comply with the correct installation procedures please refer to the Datwyler installation manual which is available separately
Core insulation low fire hazard
Core flexible class 5
Supporting members none
Materiale della guaina esterna low fire hazard
Colore della guaina esterna nero
Norma per cavi di comando flessibili per ascensori EN 50214

Documentazione