FH – Low Fire Hazard – supported
High rise - travelling height maximum 400m
Drawing according to article number 185126 - Type 8585-F
Varianti di prodotto e stock
Scaricare
Articolo n. | Stock | Prodotto | Design del cavo | Tasso di CU [kg/km] | Weight [kg/km] | GTIN / EAN |
---|---|---|---|---|---|---|
185126 | 8585-F | 30 G 1.00 + 1 x 4 x 0.34 mm² (STQ) | 335 | 1060 | 40393910077346 | |
192313 | 8880-F | 12 G 0.75 + 24 x 2 x 0.75 mm² (FTP) + 1 CX 75 Ω | 532 | 1883 | 40393910067774 |
Specifiche tecniche
Elevator suspension cable for indoor and panoramic elevators
Core | black, white numbered, G = with green-yellow core(s) |
---|---|
Pair/quad | various colours or black with white numbers |
Operating temperature | -15 °C - +70 °C |
Impronta | varios colores o impreso en negro con numeración en blanco |
Maximum free suspension | 220 m |
---|---|
Maximum travelling height | 400 m |
Maximum running speed | 12 m/s |
Acceleration | 1.2 m/s² |
Recommended loop diameter | according to table, tolerance -50/+100 mm |
To comply with the correct installation procedures please refer to the Datwyler installation manual which is available separately. |
Rated voltage Uo/U | according to table |
---|
Core insulation | low fire hazard |
---|---|
Core flexible | class 5 |
Supporting members | ST = Steel, diameter in [mm] |
Materiale della guaina esterna | low fire hazard |
Colore della guaina esterna | nero |
Standard per cavi flessibili di controllo dell'ascensore | EN 50214 |
---|