FE180 E30 CL
halogen-free, with improved fire characteristics,
with reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5.H
1 Conductor: solid / stranded
2 Fire barrier: high-peformance Keram compound
3 Insulation: cross-linked polymer, zero halogen
4 Filler: flame retardant, zero halogen
5 Inner Sheath: Polyolefin flame retardant, low smoke, zero halogen
6 Armouring: galvanised steel tape
7 Sheath: FRNC/LSZH






Descrizione
Safety cables are installed in all areas that require special protection of people and equipment against fire and fire damages and where strict security requirements must be fulfilled.
Suitable for indoor applications. For outdoor applications, protection must be provided against exposure to direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
Permitted operating temperature at conductor of +90˚C.
- Integrità del circuito (FE180) IEC 60331-11/-21 (180 minutes), VDE 0472-814 (FE180), BS 6387 C/W/Z, IEC 60331-1 (120 minutes), IEC 60331-2 (120 minutes), EN 50200 (PH120 minutes), VDE 0482-200 (PH120), AREI-RGIE Art.104-FR1
- Integrità del circuito di sistema DIN 4102-12, AREI-RGIE Art.104-FR2
- Densità del fumo IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD, SEV TP 20B/3C 3.4.3
- Zero alogeni nessun gas corrosivo IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA, SEV TPV11
- Propagazione della fiamma AREI-RGIE Art.104-F1, EN 60332-1-2, IEC 60332-1-2, SEV TP 20B/3C 3.4.1.1, VDE 0482-332-1-2
- Flame spread IEC 60332-3-24, EN 60332-3-24, VDE 0482-332-3-24, SEV TP 20B/3C 3.4.1.3, AREI-RGIE Art.104-F2
- Tensione di prova a 50Hz 3500 V
- Installation temperature -5 °C - +50 °C
- Operating temperature -45 °C - +90 °C
- Integrità del circuito E30
- Integrità dell'isolamento FE 180
- Curvatura minima durante l'installazione (anima singola) 15 x D
- Curvatura minima durante l'installazione (multicore) 12 x D
- Minimum bending radius permanent (multi core) 12 x D
- Minimum bending radius permanent (single core) 15 x D
Documentazione
Versioni
Article No. | Magazzino | Prodotto | Numero di core | Diametro mm² | Diametro esterno della guaina [mm] | Tasso di CU [kg/km] | Weight [kg/km] | Fire load [kWh/m] | Conductor | GTIN / EAN |
---|---|---|---|---|---|---|---|---|---|---|
193886
|
FE180 E30 CL | 3 | 1.5 | 11 | 43 | 210 | 0.46 kWh/m | solid | 40393910065367 | |
187199
|
FE180 E30 CL | 3 | 2.5 | 12 | 72 | 255 | 0.50 kWh/m | solid | 40393910074345 | |
191097
|
FE180 E30 CL | 3 | 4 | 14 | 115 | 373 | 0.69 kWh/m | solid | 40393910069785 | |
191121
|
FE180 E30 CL | 3 | 6 | 15.8 | 173 | 481 | 0.90 kWh/m | solid | 40393910069648 | |
188354
|
FE180 E30 CL | 3 | 10 | 18 | 288 | 651 | 1.20 kWh/m | solid | 40393910072303 | |
191595
|
FE180 E30 CL | 4 | 2.5 | 14 | 96 | 296 | 0.56 kWh/m | solid | 40393910069143 | |
187167
|
FE180 E30 CL | 4 | 4 | 16 | 154 | 408 | 0.79 kWh/m | solid | 40393910074512 | |
188352
|
FE180 E30 CL | 4 | 6 | 17 | 230 | 535 | 1.06 kWh/m | solid | 40393910072327 | |
191038
|
FE180 E30 CL | 5 | 2.5 | 14 | 120 | 388 | 0.76 kWh/m | solid | 40393910070040 | |
188350
|
FE180 E30 CL | 5 | 4 | 16 | 192 | 488 | 1.05 kWh/m | solid | 40393910072341 | |
188353
|
FE180 E30 CL | 5 | 6 | 17.5 | 288 | 640 | 1.28 kWh/m | solid | 40393910072310 | |
188397
|
FE180 E30 CL | 5 | 10 | 21 | 480 | 964 | 1.76 kWh/m | solid | 40393910072082 | |
187197
|
FE180 E30 CL | 7 | 2.5 | 16 | 168 | 476 | 0.91 kWh/m | solid | 40393910074369 | |
188355
|
FE180 E30 CL | 7 | 6 | 19 | 403 | 794 | 1.53 kWh/m | solid | 40393910072297 | |
188356
|
FE180 E30 CL | 7 | 10 | 23 | 672 | 1201 | 2.13 kWh/m | solid | 40393910072280 | |
192461
|
FE180 E30 CL | 8 | 1.5 | 15 | 115 | 403 | 0.85 kWh/m | solid | 40393910067477 | |
187128
|
FE180 E30 CL | 8 | 2.5 | 16 | 192 | 489 | 1.04 kWh/m | solid | 40393910074642 | |
191104
|
FE180 E30 CL | 8 | 4 | 18 | 308 | 684 | 1.36 kWh/m | solid | 40393910069754 |