FO Outdoor wbGGT BL / A-DQ(ZN)B2Y

Basic Line Euroclass Fca
metal-free, dry interstices,
longitudinally watertight, rodent protection

1 ≤ 12 fibres
2 Loose tube
3 Swelling tape
4 Glass armour
5 Ripcord
6 HDPE sheath

04_Propagation- 05_Spread- 06_Density- 08_System- 03_LS0H CPR_Fca

Varianti di prodotto e stock

Articolo n. Stock Loose tube constructionFibres per loose tubeNumber of used loose tubesProdottoReaction to fireColore della guaina esternaNumero di fibreFibre typeCategoria di fibraDiametro esterno della guaina [mm]Raggio di curvatura [mm]Tasso di CU [kg/km]Weight [kg/km]Tensile load [N]Crush resistance short term [N]Crush resistance continuous [N]Fire load [kWh/m]Unità di imballaggioGTIN / EAN
18659100FZ
5121FO Outdoor BL 1x12Fcanero/arancia12E9/125 G.652.D OS2OS29.41410693000250015000.606al metro40393910038705
19009200FZ
5122FO Outdoor BL 2x12Fcanero/arancia24E9/125 G.652.D OS2OS29.41410693000250015000.606al metro40393910033748
19075200FZ
5123FO Outdoor BL 3x12Fcanero/arancia36E9/125 G.652.D OS2OS29.41410693000250015000.606al metro40393910032260
19019400FZ
5124FO Outdoor BL 4x12Fcanero/arancia48E9/125 G.652.D OS2OS29.41410693000250015000.606al metro40393910033427
19019500FZ
5125FO Outdoor BL 5x12Fcanero/arancia60E9/125 G.652.D OS2OS29.41410693000250015000.606al metro40393910033410

Specifiche tecniche

Compact metal-free fibre optic outdoor cable with stranded loose tubes, up to 60 fibres.
Massimo numero di fibre 60
Campo di applicazione Outdoor
Installation temperature -10 °C - +50 °C
Storage temperature -25 °C - +70 °C
Operating temperature -25 °C - +70 °C
Impronta DATWYLER «cable type» «Datwyler designation» «DIN designation» «no. of fibres» «fibre type» «add. text» «batch no.» «meter marks»
Pulling in or blowing through thermoplastic ducts.
Laying in cable platforms, shafts and trays with low mechanical stress.
Direct burial.
Tensile performance IEC 60794-1-21 E1
Crush resistance IEC 60794-1-21 E3
Impact IEC 60794-1-21 E6
Repeated bending IEC 60794-1-21 E7
Torsion IEC 60794-1-21 E11
Bend IEC 60794-1-22 F5
Reaction to fire EN 13501-6
Euroclass Fca
Zero alogeni nessun gas corrosivo IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2
Armatura (protezione per roditori) protetto dai roditori
Materiale della guaina esterna HDPE

Documentazione