FO Outdoor ZKT Micro / A-DQ(ZN)2Y, Fca

Micro, up to 24 fibres, Euroclass Fca
metal-free, non-armoured,
dry interstices, longitudinally watertight

1 ≤ 24 fibres
2 Loose tube
3 Aramid yarn
4 Ripcord
5 HDPE sheath

04_Propagation- 05_Spread- 06_Density- 08_System- 03_LS0H CPR_Fca

Product variants & stock

Article No. Stock Loose tube constructionNumber of used loose tubesFibres per loose tubeProductReaction to fireOuter sheath colourNumber of fibresFibre typeFibre categoryOuter sheath diameter [mm]Bending radius [mm]Weight [kg/km]Tensile load [N]Crush resistance short term [N]Crush resistance continuous [N]Fire load [kWh/m]Packing unitGTIN / EAN
19170200FZ
112FO Outdoor ZKT Micro 1x2Fcablack/orange2E9/125 G.652.D BLOOS2410013.250016006000.165by the metre40393910029925
19065800FZ
114FO Outdoor ZKT Micro 1x4Fcablack/orange4E9/125 G.652.D BLOOS2410013.350016006000.165by the metre40393910032482
19170300FZ
116FO Outdoor ZKT Micro 1x6Fcablack/orange6E9/125 G.652.D BLOOS2410013.450016006000.165by the metre40393910029918
19170400FZ
118FO Outdoor ZKT Micro 1x8Fcablack/orange8E9/125 G.652.D BLOOS2410013.550016006000.165by the metre40393910029901
19170500FZ
1110FO Outdoor ZKT Micro 1x10Fcablack/orange10E9/125 G.652.D BLOOS2410013.650016006000.165by the metre40393910029895
19022700FZ
1112FO Outdoor ZKT Micro 1x12Fcablack/orange12E9/125 G.652.D BLOOS2410013.750016006000.165by the metre40393910033199
19123500FZ
1124FO Outdoor ZKT Micro 1x24Fcablack/orange24E9/125 G.652.D BLOOS2410013.950016006000.165by the metre40393910031546

Technical specifications

Very thin, metal-free fiber optic outdoor cable with up to 24 fibres in one central loose tube.
Easily cut-back, installation friendly cable construction.
Maximum number of fibres 24
Installation temperature -5 °C - +50 °C
Storage temperature -40 °C - +70 °C
Operating temperature -40 °C - +70 °C
Imprint DATWYLER FO Outdoor ZKT Micro / A-DQ(ZN)2Y «No. of fibres» «Fibre type» «Batch no.» MADE IN SWITZERLAND «Receiver wave receiver wave» «Meter marks»
Field of application Outdoor
Datwyler recommends blowing in micro and mini cables in an ambient temperature range from -2°C to +35°C.
For installation, a blow-in device with a rubber pull-in bead is recommended.
FTTx, Fibre-to-the-home networks.
Optimised for injection into microducts.
Tensile performance IEC 60794-1-21 E1
Crush resistance IEC 60794-1-21 E3
Impact IEC 60794-1-21 E4
Repeated bending IEC 60794-1-21 E6
Torsion IEC 60794-1-21 E7
Bend IEC 60794-1-21 E11
Temperature cycling IEC 60794-1-22 F1
Water penetration IEC 60794-1-22 F5
Reaction to fire EN 13501-6
Euroclass Fca
Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2
Armouring (rodent protection) non-armoured
Outer sheath material HDPE

Documentation