FM - FRNC
Mid rise - travelling height maximum 150m
Drawing according to article number 185124 ; Type 8696-F
Product variants & stock
Download
| Article No. | Stock | Product | Cable design | CU rate [kg/km] | Weight [kg/km] | GTIN / EAN |
|---|---|---|---|---|---|---|
| 185127 | 8622-F | 12 G 1.00 + 1 CX 75 Ω | 139 | 484 | 40393910077339 | |
| 185124 | 8696-F | 12 G 1.00 + 1 x 4 x 0.34 mm² (STQ) | 142 | 486 | 40393910077360 | |
| 191094 | 8872-F | 3 G 2.50 + 14 x 1.00 + 4 x 2 x 0.50 mm² (FTP) | 232 | 818 | 40393910069815 |
Technical specifications
Elevator suspension cable for indoor and panoramic elevators.
| Pair/quad | various colours or black with white numbers |
|---|---|
| Core | black, white numbered, G = with green-yellow core(s) |
| Coax | black |
| Operating temperature | -15 °C - +70 °C |
| Rated voltage Uo/U | according to table |
|---|
| To comply with the correct installation procedures please refer to the Datwyler installation manual which is available separately |
| Core insulation | low fire hazard |
|---|---|
| Core flexible | class 5 |
| Supporting members | HTF = High tensile fibre |
| Outer sheath material | low fire hazard |
| Outer sheath colour | black |
| Standard for flexible lift control cables | EN 50214 |
|---|
| Maximum travelling height | 150 m |
|---|---|
| Maximum free suspension | 80 m |
| Maximum running speed | 6.3 m/s |
| Recommended loop diameter | according to table, tolerance -50/+100 mm |
| Acceleration | 1.2 m/s² |