FL –FRNC - without data elements

Low rise - travelling height maximum 80m

Drawing according to article number 191110 ; Type 8511-F

04_Propagation 05_Spread- 06_Density 03_LS0H

Product variants & stock

Article No. Stock ProductCable designCU rate [kg/km]Weight [kg/km]GTIN / EAN
191110
8511-F12 G 0.75 mm²8725940393910069716
185125
8511-F18 G 0.75 mm²13038240393910077353
191112
8511-F24 G 0.75 mm²17351140393910069693

Technical specifications

Elevator suspension cable for indoor and panoramic elevators.
Acceleration 0.8 m/s²
Maximum running speed 4 m/s
Maximum travelling height 80 m
Maximum free suspension 45 m
Recommended loop diameter according to table, tolerance -50/+100 mm
Pair/quad various colours or black with white numbers
Core black, white numbered, G = with green-yellow core(s)
Coax black
Operating temperature -15 °C - +70 °C
Rated voltage Uo/U according to table
To comply with the correct installation procedures please refer to the Datwyler installation manual which is available separately
Core insulation low fire hazard
Core flexible class 5
Supporting members none
Outer sheath material low fire hazard
Outer sheath colour black
Standard for flexible lift control cables EN 50214

Documentation