CU 662 4P
Data cable, U/UTP, Category 6, AWG23, Euroclass Eca
300 MHz
This product is not available in your region!
1 Inner conductor: AWG23/0,55 mm Bare Copper wire
2 PE insulated conductor: 0.98 mm ∅ PE
3 Pair seperator
4 Outer sheath: FRNC/LSoH orange RAL 2003, FR/PVC grey RAL 7037
Product variants & stock
Article No. | Stock | Product | Reaction to fire | Dimensions n x p x [mm (AWG)] | Outer sheath colour | Outer sheath dimensions [mm] | CU rate [kg/km] | Weight [kg/km] | Fire load [kWh/m] | Packing unit | GTIN / EAN |
---|---|---|---|---|---|---|---|---|---|---|---|
24014100EP | CU 662 4P | Eca | 4 x 2 x 0.55 (AWG23) | orange | 6 | 19.4 | 41 | 0.17 | 305 m PullQuick box | 40393910015812 | |
24014100ES | CU 662 4P | Eca | 4 x 2 x 0.55 (AWG23) | orange | 6 | 19.4 | 49 | 0.17 | 305 m reel in box | 40393910015805 | |
24013910ES | CU 662 4P | Eca | 4 x 2 x 0.55 (AWG23) | grey | 6 | 19.4 | 49 | 0.20 | 305 m reel in box | 40393910090017 |
Technical specifications
Electrically and mechanically advanced quality Cat.6 data cable - fulfils the requirements of ISO/IEC 11801, IEC 61156-5, EN 50173-1 and EN 50288-6-1.
Robust cable design with reliable electrical performance thanks to stabilising element.
Very good NEXT reserve due to cable construction with a pair separator (cross).
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.
Tensile strength (4P) | 91 N |
---|---|
Minimum bending radius (during installation) | 45 mm |
Minimal crush resistance / 10cm | 1000 N |
Minimum number of impacts | 10 |
AWG | 23 |
Solid / Flex | Solid wire |
Minimum bending radius (permanently installed) | 22.5 mm |
Data cable for structured premesis cabling. For the transmission of digital and analogue voice, video and data signals. Suitable for all ICT network applications up to class E applications (250 MHz) in accordance with EN 50173-1 and ISO/IEC 11801. Applicable for Power over Ethernet (PoE) / PoE+. |
Category | Cat.6 |
---|---|
GBit/s | Up to 1 Gbit/s |
Loop resistance at 20 °C | 155 Ω/km |
Operating capacity | 50 pF/m |
Impedance at 100 MHz, ±5Ω | 100 Ω |
NVP % | 67 |
Delay skew | 20 ns/100 m |
Shielding | unshielded |
TCL | 50 dB |
Segregation class | b |
Installation temperature | 0 °C - +50 °C |
---|---|
Operating temperature | -20 °C - +60 °C |
Wire colour | white/blue-white, white/orange-white, white/green-white, white/brown-white (with length stripes) |
Imprint | DATWYLER «cable type» «additional text» «batch number» «meter marks» |
Field of application | Indoor |
Reaction to fire | EN 13501-6 |
---|---|
Euroclass | Eca |
Smoke density | AREI-RGIE Art.104-SD - applies to FRNC/LS0H, EN 61034-1/-2, IEC 61034-1/-2, VDE 0482-1034-1/-2 |
Zero halogen no corrosive gases | AREI-RGIE Art.104-SA, EN 60754-1/-2, IEC 60754-1/-2, VDE 0482-754-1/-2 |
Flame propagation | AREI-RGIE Art.104-F1, EN 60332-1-2, IEC 60332-1-2, VDE 0482-332-1-2 |
Cables standard | ISO/IEC 61156-5, EN 50288-6-1 |
Cat./Class | Cat.6 / Class E |
PoE | IEEE 802.3bt Type 4 (100W) |
Outer sheath material | FRNC/LSZH |
---|
Documentation
-
Tender text
Download UNKNOWN [ 72.138 KB ]
-
Tender text
Download UNKNOWN [ 75.285 KB ]
-
Tender text
Download UNKNOWN [ 68.425 KB ]
-
Datasheet
Download PDF [ 171.594 KB ]
-
Datasheet
Download PDF [ 172.981 KB ]
-
Datasheet
Download PDF [ 171.962 KB ]
-
Datasheet
Download PDF [ 174.24 KB ]
-
Datasheet
Download PDF [ 174.142 KB ]
-
Datasheet
Download PDF [ 173.129 KB ]