CU 6060 4P

Data cable, S/FTP, Category 6, AWG23, Euroclass B2ca
300 MHz

1 Inner conductor: AWG23 Bare copper wire
2 PE insulated conductor: 1.3 mm Ø
3 Screen (pair): Alu PETP foil
4 Overall screen: Tinned braided copper
5 Outer sheath: FRNC/LS0H

02_PoEp_gn CPR_Eca CPR_Cca CPR_Dca 06_Density 10_Schielded_EN CPR_B2ca 03_LS0H 05_Spread 01_RoHS CPR_Fca 08_System- 04_Propagation

Product variants & stock

Article No. Stock ProductReaction to fireDimensions n x p x [mm (AWG)]Outer sheath dimensions [mm]CU rate [kg/km]Weight [kg/km]Fire load [kWh/m]Packing unitGTIN / EAN
19432800BL
CU 6060 4PB2ca-s1a,d1,a14 x 2 x 0.55 (AWG23)7.626.4470.14500 m drum40393910023169

Technical specifications

Electrically and mechanically superior quality Cat.6 data cable - exceeds the requirements of ISO/IEC 11801, IEC 61156-5, EN 50173-1 and EN 50288-5-1.
Excellent shielding effect due to individually screened pairs and overall copper braid.
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.
Data cable for structured premises cabling.
For the transmission of digital and analogue voice, video and data signals.
Suitable for all ICT network applications up to class E applications (250 MHz) in accordance with EN 50173-1 and ISO/IEC 11801.
Applicable for Power over Ethernet (PoE) / PoE+ / 4PPoE.
AWG 23
Solid / Flex Solid wire
Minimum bending radius (permanently installed) 30 mm
Minimum bending radius (during installation) 65 mm
Tensile strength (4P) 95 N
Minimum number of impacts 10
Minimal crush resistance / 10cm 1000 N
Category Cat.6
GBit/s Up to 10 Gbit/s
Loop resistance at 20 °C 146 Ω/km
Operating capacity 42 pF/m
Impedance at 100 MHz, ±5Ω 100 Ω
NVP % 80
Delay skew 4 ns/100 m
Shielding shielded
Near end unbalance attenuation LCL at 1-600 MHz 40 dB
Transfer impedance 1/10/30 MHz < 9/12/30 mΩ/m
Coupling attenuation 70 dB
Segregation class c
Installation temperature 0 °C - +50 °C
Operating temperature -20 °C - +60 °C
Wire colour white/blue, white/orange, white/green, white/brown, according to IEC 60189 and IEC 60708
Imprint DATWYLER «cable type» «additional text» «batch number» «meter marks»
Field of application Indoor
Reaction to fire EN 13501-6
Euroclass B2ca
Smoke density IEC 61034-1/-2, EN 61034-1/-2
Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2
Flame propagation IEC 60332-1-2, EN 60332-1-2
Flame spread IEC 60332-3-24, EN 60332-3-24
Cables standard ISO/IEC 61156-5, EN 50288-5-1
Cat./Class Cat.6 / Class E
PoE IEEE 802.3at
Outer sheath material FRNC/LSZH
Outer sheath colour orange

Documentation