FH - FRNC
High rise - travelling height maximum 400m
Drawing according to article number 192898; Type 8866-F
Product variants & stock
Download
| Article No. | Stock | Product | Cable design | CU rate [kg/km] | Weight [kg/km] | GTIN / EAN |
|---|---|---|---|---|---|---|
| 185126 | 8585-F | 30 G 1.00 + 1 x 4 x 0.34 mm² (STQ) | 335 | 1060 | 40393910077346 | |
| 191114 | 8859-F | 12 G 2.00 + 30 x 1.00 + 7 x 2 x 0.50 (FTP) + 3 x 4 x 0.50 mm² (STQ) | 698 | 1929 | 40393910069679 | |
| 192313 | 8880-F | 12 G 0.75 + 24 x 2 x 0.75 mm² (FTP) + 1 CX 75 Ω | 532 | 1883 | 40393910067774 | |
| 191483 | 8866-F | 10 G 2.50 + 7 x 1.50 + 6 x 1.00 + 12 x 2 x 0.75 mm² (FTP) + 4 FO G50/125 µm | 616 | 2184 | 40393910069297 |
Technical specifications
Elevator suspension cable for indoor and panoramic elevators
| Pair/quad | various colours or black with white numbers |
|---|---|
| Core | black, white numbered, G = with green-yellow core(s) |
| Operating temperature | -15 °C - +70 °C |
| Imprint | varios colores o impreso en negro con numeración en blanco |
| Rated voltage Uo/U | according to table |
|---|
| To comply with the correct installation procedures please refer to the Datwyler installation manual which is available separately. |
| Core insulation | low fire hazard |
|---|---|
| Core flexible | class 5 |
| Supporting members | ST = Steel, diameter in [mm] |
| Outer sheath material | low fire hazard |
| Outer sheath colour | black |
| Standard for flexible lift control cables | EN 50214 |
|---|
| Maximum travelling height | 400 m |
|---|---|
| Maximum free suspension | 220 m |
| Maximum running speed | 12 m/s |
| Recommended loop diameter | according to table, tolerance -50/+100 mm |
| Acceleration | 1.2 m/s² |