(N)HXCH FE180 E90 B2ca
halogen-free, with improved fire characteristics,
with reference to VDE 0266 and CENELEC HD 604 S1,
circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331,
System Circuit Integrity E90 in accordance with DIN 4102-12
Reaction to fire according to EN 13501-6
1 Conductor: solid/stranded
2 Fire barrier: high-peformance Keram compound
3 Insulation: cross-linked polymer, zero halogen
4 Filler: flame retardant, zero halogen
5 Concentric conductor: bare copper wire
6 Reinforcing helix: bare copper tape
7 Separator: plastic tape
8 Sheath: FRNC/LSZH






Descrizione
Cables with intrinsic fire resistance are installed in all areas that require special protection of people and equipment against fire and fire damages and where strict security requirements must be fulfilled. Suitable for indoor applications. For outdoor applications, protection must be provided against exposure to direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used. These cables correspond to the demands of System Circuit Integrity E90* in accordance with DIN 4102-12. System Circuit Integrity is guaranteed at an operating voltage up to 400V.
Permitted operating temperature at conductor of +90˚C.
Suitable according to VKF fire protection guideline in escape routes and in tunnels according to Astra guideline 13022.
- For use in critical fire safety infrastructure (in compliance with VKF, ASTRA, Tunnels Directive, etc.), particularly in escape routes and emergency lines.
- Conduttore concentrico Bare copper wires with reinforced helix
- Colore della guaina esterna arancia
- Integrità del circuito (FE180) IEC 60331-11/-21 (180 minutes), VDE 0472-814 (FE180), IEC 60331-1 (120 minutes), IEC 60331-2 (120 minutes), EN 50200 (PH120 minutes), VDE 0482-200 (PH120), AREI-RGIE Art.104-FR1
- Integrità del circuito di sistema DIN 4102-12, VdS 3423 (più di 16,0 mm²), AREI-RGIE Art.104-FR2
- Reaction to fire (Euroclasses) EN 13501-6: B2ca, EN 50399
- Densità del fumo IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD
- Zero alogeni nessun gas corrosivo IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA
- Propagazione della fiamma AREI-RGIE Art.104-F1, EN 60332-1-2, IEC 60332-1-2, VDE 0482-332-1-2
- Flame spread IEC 60332-3-22/-24, EN 60332-3-22/-24, VDE 0482-332-3-22/-24, AREI-RGIE Art.104-F2
- Tensione di prova a 50Hz 4000 V
- Installation temperature -5 °C - +50 °C
- Operating temperature -45 °C - +90 °C
- Integrità del circuito E90
- Integrità dell'isolamento FE 180
- Curvatura minima durante l'installazione (multicore) 12 x D
- Minimum bending radius permanent (multi core) 12 x D
Documentazione
Versioni
Article No. | Magazzino | Prodotto | Reaction to fire | Colore della guaina esterna | Numero di core | Diametro mm² | Diametro esterno della guaina [mm] | Tasso di CU [kg/km] | Weight [kg/km] | Fire load [kWh/m] | Conductor | Construction | Unità di imballaggio | GTIN / EAN |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
18607100BZ
|
(N)HXCH FE180 E90 3 x 1.5/1.5 | B2ca-s1a,d1,a1 | arancia | 3 | 1.5/1.5 | 13.2 | 66 | 246 | 0.599 kWh/m | solid | 3L | al metro | 40393910039795 | |
18619500BZ
|
(N)HXCH FE180 E90 3 x 2.5/2.5 | B2ca-s1a,d1,a1 | arancia | 3 | 2.5/2.5 | 14.1 | 104 | 303 | 0.784 kWh/m | solid | 3L | al metro | 40393910039207 | |
18619700BZ
|
(N)HXCH FE180 E90 3 x 4/4 | B2ca-s1a,d1,a1 | arancia | 3 | 4/4 | 15.6 | 161 | 400 | 0.771 kWh/m | solid | 3L | al metro | 40393910039184 | |
18727800BZ
|
(N)HXCH FE180 E90 3 x 6/6 | B2ca-s1a,d1,a1 | arancia | 3 | 6/6 | 16.9 | 240 | 521 | 0.921 kWh/m | solid | 3L | al metro | 40393910037173 | |
17241700BZ
|
(N)HXCH FE180 E90 3 x 35/16 | B2ca-s1a,d1,a1 | arancia | 3 | 35/16 | 29 | 1190 | 1941 | 2.267 kWh/m | stranded | 3L | al metro | 40393910043600 | |
18740800BZ
|
(N)HXCH FE180 E90 3 x 50/25 | B2ca-s1a,d1,a1 | arancia | 3 | 50/25 | 32.5 | 1723 | 2545 | 2.729 kWh/m | stranded | 3L | al metro | 40393910036961 | |
18740900BZ
|
(N)HXCH FE180 E90 3 x 70/35 | B2ca-s1a,d1,a1 | arancia | 3 | 70/35 | 37.6 | 2410 | 3536 | 3.542 kWh/m | stranded | 3L | al metro | 40393910036954 | |
18741000BZ
|
(N)HXCH FE180 E90 3 x 95/50 | B2ca-s1a,d1,a1 | arancia | 3 | 95/50 | 41.9 | 3296 | 4598 | 4.285 kWh/m | stranded | 3L | al metro | 40393910036947 | |
18741100BZ
|
(N)HXCH FE180 E90 3 x 120/70 | B2ca-s1a,d1,a1 | arancia | 3 | 120/70 | 45.3 | 4236 | 5688 | 5.112 kWh/m | stranded | 3L | al metro | 40393910036930 | |
18741200BZ
|
(N)HXCH FE180 E90 3 x 150/70 | B2ca-s1a,d1,a1 | arancia | 3 | 150/70 | 50 | 5100 | 6911 | 5.889 kWh/m | stranded | 3L | al metro | 40393910036923 | |
18607200BZ
|
(N)HXCH FE180 E90 4 x 1.5/1.5 | B2ca-s1a,d1,a1 | arancia | 4 | 1.5/1.5 | 14.1 | 81 | 280 | 0.677 kWh/m | solid | 3LN | al metro | 40393910039788 | |
18619600BZ
|
(N)HXCH FE180 E90 4 x 2.5/2.5 | B2ca-s1a,d1,a1 | arancia | 4 | 2.5/2.5 | 15.1 | 128 | 350 | 0.754 kWh/m | solid | 3LN | al metro | 40393910039191 | |
18619800BZ
|
(N)HXCH FE180 E90 4 x 4/4 | B2ca-s1a,d1,a1 | arancia | 4 | 4/4 | 16.7 | 200 | 464 | 0.87 kWh/m | solid | 3LN | al metro | 40393910039177 | |
18619900BZ
|
(N)HXCH FE180 E90 4 x 6/6 | B2ca-s1a,d1,a1 | arancia | 4 | 6/6 | 18.1 | 297 | 612 | 1.051 kWh/m | solid | 3LN | al metro | 40393910039160 | |
18620000BZ
|
(N)HXCH FE180 E90 4 x 10/10 | B2ca-s1a,d1,a1 | arancia | 4 | 10/10 | 20.1 | 504 | 858 | 1.25 kWh/m | solid | 3LN | al metro | 40393910039153 | |
18613100BZ
|
(N)HXCH FE180 E90 4 x 16/16 | B2ca-s1a,d1,a1 | arancia | 4 | 16/16 | 25.3 | 796 | 1396 | 1.772 kWh/m | stranded | 3LN | al metro | 40393910039764 | |
18613200BZ
|
(N)HXCH FE180 E90 4 x 25/16 | B2ca-s1a,d1,a1 | arancia | 4 | 25/16 | 28.9 | 1142 | 1895 | 2.568 kWh/m | stranded | 3LN | al metro | 40393910039757 | |
18613300BZ
|
(N)HXCH FE180 E90 4 x 35/16 | B2ca-s1a,d1,a1 | arancia | 4 | 35/16 | 31.6 | 1526 | 2378 | 2.568 kWh/m | stranded | 3LN | al metro | 40393910039740 | |
18613400BZ
|
(N)HXCH FE180 E90 4 x 50/25 | B2ca-s1a,d1,a1 | arancia | 4 | 50/25 | 36.7 | 2203 | 3245 | 3.374 kWh/m | stranded | 3LN | al metro | 40393910039733 | |
18613500BZ
|
(N)HXCH FE180 E90 4 x 70/35 | B2ca-s1a,d1,a1 | arancia | 4 | 70/35 | 41.3 | 3082 | 4371 | 4.08 kWh/m | stranded | 3LN | al metro | 40393910039726 | |
18613600BZ
|
(N)HXCH FE180 E90 4 x 95/50 | B2ca-s1a,d1,a1 | arancia | 4 | 95/50 | 46.4 | 4208 | 5731 | 5.179 kWh/m | stranded | 3LN | al metro | 40393910039719 | |
18613700BZ
|
(N)HXCH FE180 E90 4 x 120/70 | B2ca-s1a,d1,a1 | arancia | 4 | 120/70 | 50.1 | 5388 | 7078 | 5.858 kWh/m | stranded | 3LN | al metro | 40393910039702 | |
18613800BZ
|
(N)HXCH FE180 E90 4 x 150/70 | B2ca-s1a,d1,a1 | arancia | 4 | 150/70 | 55.3 | 6540 | 8631 | 7.11 kWh/m | stranded | 3LN | al metro | 40393910039689 | |
18613900BZ
|
(N)HXCH FE180 E90 4 x 185/95 | B2ca-s1a,d1,a1 | arancia | 4 | 185/95 | 60.8 | 8159 | 10727 | 8.61 kWh/m | stranded | 3LN | al metro | 40393910039665 | |
18614000BZ
|
(N)HXCH FE180 E90 4 x 240/120 | B2ca-s1a,d1,a1 | arancia | 4 | 240/120 | 69.2 | 10546 | 13949 | 10.885 kWh/m | stranded | 3LN | al metro | 40393910039658 | |
18607302BZ
|
(N)HXCH FE180 E90 7 x 1.5/2.5 | B2ca-s1b,d1,a1 | arancia | 7 | 1.5/2.5 | 16.1 | 133 | 390 | 0.884 kWh/m | solid | 7L | al metro | 40393910039771 | |
19109602BZ
|
(N)HXCH FE180 E90 7 x 2.5/2.5 | B2ca-s1b,d1,a1 | arancia | 7 | 2.5/2.5 | 17.3 | 200 | 484 | 0.994 kWh/m | solid | 7L | al metro | 40393910031782 | |
18741502BZ
|
(N)HXCH FE180 E90 12 x 1.5/2.5 | B2ca-s1b,d1,a1 | arancia | 12 | 1.5/2.5 | 20.2 | 205.8 | 589 | 1.308 kWh/m | solid | 12L | al metro | 40393910036916 |