Tornare a: Cavo esterno

FO Outdoor ZT S-Micro / A-D2Y

metal-free, non-armoured, dry interstices, longitudinally watertight

1 ≤ 24 fibres
2 PE sheath

Descrizione

Very thin, metal-free fibre optic outdoor cable with up to 24 fibres in one central loose tube.
Easily cut back, installation friendly cable construction.

  • FTTx, Fibre-to-the-home networks.
    Optimised for injection into microducts.
  • Materiale della guaina esterna PBT
  • Armatura (protezione per roditori) non-armoured
  • Tensile performance IEC 60794-1-21 E1
  • Crush resistance IEC 60794-1-21 E3
  • Impact IEC 60794-1-21 E4
  • Repeated bending IEC 60794-1-21 E6
  • Torsion IEC 60794-1-21 E7
  • Bend IEC 60794-1-21 E11
  • Variazione di temperatura IEC 60794-1-22 F1
  • Water penetration IEC 60794-1-22 F5
  • Reaction to fire (Euroclasses) EN 13501-6: Fca
  • Zero alogeni nessun gas corrosivo IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2
  • Datwyler raccomanda di soffiare nei cavi micro e mini in un intervallo di temperatura ambiente da -2°C a +35°C.Per l'installazione, si raccomanda un dispositivo di soffiaggio con un cordone di gomma.
  • Installation temperature -5 °C - +50 °C
  • Storage temperature -25 °C - +70 °C
  • Operating temperature -25 °C - +70 °C
  • Campo di applicazione Outdoor
  • Impronta DATWYLER «cable type» «Datwyler designation» «DIN designation» «no. of fibres» «fibre type» «add. text» «batch no.» «meter marks»
  • Massimo numero di fibre 24

Documentazione

ENDENLFRCNESIT
ASS_PIM_tenderText file-icon ASS_PIM_tenderText file-icon file-icon file-icon file-icon file-icon
Scheda tecnica Scheda tecnica Scheda tecnica Scheda tecnica Scheda tecnica file-icon Scheda tecnica Scheda tecnica

Versioni

Article No.MagazzinoProdottoReaction To FireColore della guaina esternaNumero di fibreFibre typeDiametro esterno della guaina [mm]Raggio di curvatura [mm]Weight [kg/km]Tensile load [N]Crush resistance short term [N]Crush resistance continuous [N]Fire load [kWh/m]Unità di imballaggioGTIN / EANCategoria di fibraFibres per loose tubeLoose tube constructionNumber of used loose tubes
19343400FZ FO Outdoor S-Micro 1x4Fcanero4E9/125 G.652.D BLO2.4 mm40 mm510012004000.12 kWh/mal metro40393910026122OS2411
19604800FZ FO Outdoor S-Micro 1x6Fcanero6E9/125 G.652.D BLO2.4 mm40 mm510012004000.12 kWh/mal metro40393910020434OS2611
19345900FZ FO Outdoor S-Micro 1x6Fcanero6G50/125 OM32.4 mm40 mm510012004000.12 kWh/mal metro40393910026016OM3611
19346000FZ FO Outdoor S-Micro 1x12Fcanero12E9/125 G.652.D BLO2.4 mm40 mm510012004000.12 kWh/mal metro40393910026009OS21211
19343500FZ FO Outdoor S-Micro 1x12Fcanero12G50/125 OM42.4 mm40 mm510012004000.12 kWh/mal metro40393910026115OM41211
19343300FZ FO Outdoor S-Micro 1x24Fcanero24E9/125 G.652.D BLO2.4 mm40 mm610012004000.12 kWh/mal metro40393910026139OS22411
19607000FZ FO Outdoor S-Micro 1x24Fcanero24G50/125 OM42.4 mm40 mm610012004000.12 kWh/mal metro40393910020182OM42411