CU 6502 4P / 2x4P F8

Data cable, U/FTP, Category 6A, AWG23, Euroclass Cca
650 MHz

1 Inner conductor: AWG23 Bare copper wire
2 PE insulated conductor: 1.3 mm Ø
3 Screen (pair): Alu PETP foil
4 Drain wire: Tinned copper wire
5 Outer sheath: FRNC/LS0H orange RAL 2003

01_RoHS 04_Propagation 05_Spread- 02_PoE 10_Schielded_EN 06_Density 08_System- 03_LS0H CPR_Cca CPR_Dca CPR_Eca

Varianti di prodotto e stock

Articolo n. Stock ProdottoReaction to fireDimensions n x p x [mm (AWG)]Dimensioni della guaina esterna [mm]Tasso di CU [kg/km]Weight [kg/km]Fire load [kWh/m]Unità di imballaggioGTIN / EAN
19145502CL
CU 6502 2x4PCca-s1b,d1,a12 x (4 x 2 x 0.55 (AWG23))7.0 x 14.340.0960.3500 m tamburo40393910030716
19145300CK
CU 6502 4PCca-s1a,d1,a14 x 2 x 0.55 (AWG23)6.820.0480.151000 m tamburo40393910030945

Specifiche tecniche

Electrically and mechanically improved quality Cat.6A data cable - fulfils the requirements of ISO/IEC 11801, IEC 61156-5, EN 50173-1 and EN 50288-10-1. Good shielding effect due to individually screened pairs. Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.
AWG 23
Resistenza alla trazione (4P) 95 N
Resistenza alla trazione (2x4P) 190 N
Curvatura minima durante l'installazione 56 mm
Minimum bending radius permanently installed 28 mm
Resistenza minima allo schiacciamento / 10cm 1000 N
Minimum number of impacts 10
Solid / Flex stabile
Segregation class c
Categoria Cat.6A
Loop resistance at 20 °C 150 Ω/km
Operating capacity 42 pF/m
Ritardo Skew 5 ns/100 m
Impedenza a 100 MHz, ±5Ω 100 Ω
Transfer impedance 1/10/30 MHz < 50/100/200 mΩ/m
Near end unbalance attenuation LCL at 1-600 MHz 40 dB
NVP % 79
Attenuazione di accoppiamento 55 dB
GBit/s A 10 Gbit/s
Schermatura schermati
Data cable for structured premises cabling.
For the transmission of digital and analogue voice, video and data signals.
Suitable for all ICT network applications up to class EA applications (500 MHz) in accordance with EN 50173-1 and ISO/IEC 11801.
Applicable for Power over Ethernet (PoE) / PoE+.
Colore del filo bianco/blu, bianco/arancio, bianco/verde, bianco/marrone, in conformità alle norme IEC 60189 e IEC 60708
Campo di applicazione Interno
Installation temperature 0 °C - +50 °C
Operating temperature -20 °C - +60 °C
Impronta DATWYLER «cable type» «additional text» «batch number» «meter marks»
Reaction to fire EN 13501-6
Euroclass Cca
Densità del fumo IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD
Zero alogeni nessun gas corrosivo IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA
Propagazione della fiamma AREI-RGIE Art.104-F1, EN 60332-1-2, IEC 60332-1-2, VDE 0482-332-1-2
Standard dei cavi ISO/IEC 61156-5, EN 50288-10-1
Cat./Class Cat.6A / Class EA
PoE IEEE 802.3bt Type 4 (100W)
Materiale della guaina esterna FRNC/LSZH
Colore della guaina esterna arancia

Documentazione