SMDC – Single-rack

up to 10 kVA, internal or outdoor condenser

Variantes de produits et stock

Numéro d'article Inventaire ProduitDimensions extérieuresCooling capacity [kW]Maximum UPS capacity [kVA]Charge informatiqueEspace disponibleCooling / CondenserInput powerPoids [kg]GTIN / EAN
40014180ZY
SMDC 3kVA42 U, 2000 x 800 x 1400 mm3.532.7 kW24 - 27 URack-mounted / internal220 - 240 VAC, 1Ph+N+PE 50/60 Hz480 kg40393910220995
40014190ZY
SMDC 6kVA42 U, 2000 x 1100 x 1400 mm5.565.4 kW27 - 31 UIn-row / outdoor220~240 VAC, 1Ph+N+PE 50/60 Hz800 kg40393910221008
40014630ZY
SMDC 10kVA42 U, 2000 x 1100 x 1400 mm12.5109 kW24 - 27 UIn-row / outdoor380 - 415 VAC, 3Ph+N+PE 50/60 Hz800 kg40393910221169

Spécifications techniques

The Smart Modular Data Centre (SMDC) is a scalable, pre-assembled, plug-and-play solution designed for edge computing and optimised for rapid deployment.
Each single-rack SMDC features a configurable power supply unit and a redundant cooling system, providing seamless scalability and technology upgrades with little additional cost or disruption.
This single-rack solution ensures a capacity of up to 10 kVA. It consists of a 42U rack, an integrated intelligent power distribution, an uninterruptible power supply (UPS) and a compact cooling system – either integrated up to 3.5 kW or with an in-row cooler and external condenser with a capacity of up to 12.5 kW.
It also includes a fire extinguishing system, air gap sealing and comprehensive software for infrastructure management.
Application The single-rack SMDC supports edge computing, operating smart facilities with IoT devices, remote or branch offices or serves as a floor distributor (FD).
Advanced applications include technologies such as AI, AR, VR and automation systems that require flexible, scalable and energy-efficient real-time data processing.
Ventilation d'urgence Top of the rack and front door, extracting hot air from the rack in case of cooling failure
Boîtier d'alimentation PDM6 input breaker, 63A/1P*1 (3 or 6 kVA) / PDM10 input breaker, 125A/3P*1 (10 kVA)
PDU Intelligent power management
Capacité de l'onduleur up to 10 kVA
Prolongation du temps d'autonomie de l'ASI (en option) 10 to 15 minutes
Refroidissement in rack (up to 3.5 kW), in row (up to 12.5 kW)
Interface utilisateur 10.4" touch screen and remote web interface
Capteurs Cooling system, UPS, power usage effectiveness (PUE), iPDU*, IT load, access control*, temperature, humidity and alarm status
Alarme et notification Sound and light alarm with SMS and email notification
Contrôle d'accès Card or keypad
Suppression des incendies NOVEC 1230 rack mounted (2U)*
Porte avant avec un double vitrage trempé de 5 mm (ne s’applique pas aux refroidisseurs en rangée)
Porte arrière en tôle d’acier massive
Panneaux latéraux amovible, avec boulon de mise à la terre
Panneaux haut entrée de câble possible
Panneaux bas entrée de câble possible
Profil de montage 2 paires de profils verticaux 19" (avant / arrière)