FH - FRNC
High rise - travelling height maximum 400m
Drawing according to article number 192898; Type 8866-F
Variantes de produits et stock
Télécharger
| Numéro d'article | Inventaire | Produit | Conception du câble | Poids CU [kg/km] | Poids [kg/km] | GTIN / EAN |
|---|---|---|---|---|---|---|
| 185126 | 8585-F | 30 G 1.00 + 1 x 4 x 0.34 mm² (STQ) | 335 | 1060 | 40393910077346 | |
| 191114 | 8859-F | 12 G 2.00 + 30 x 1.00 + 7 x 2 x 0.50 (FTP) + 3 x 4 x 0.50 mm² (STQ) | 698 | 1929 | 40393910069679 | |
| 192313 | 8880-F | 12 G 0.75 + 24 x 2 x 0.75 mm² (FTP) + 1 CX 75 Ω | 532 | 1883 | 40393910067774 | |
| 191483 | 8866-F | 10 G 2.50 + 7 x 1.50 + 6 x 1.00 + 12 x 2 x 0.75 mm² (FTP) + 4 FO G50/125 µm | 616 | 2184 | 40393910069297 |
Spécifications techniques
Elevator suspension cable for indoor and panoramic elevators
| Paire/quad | various colours or black with white numbers |
|---|---|
| Coeur | black, white numbered, G = with green-yellow core(s) |
| Température de fonctionnement | -15 °C - +70 °C |
| Impression | varios colores o impreso en negro con numeración en blanco |
| Tension nominale Uo/U | according to table |
|---|
| Application | To comply with the correct installation procedures please refer to the Datwyler installation manual which is available separately. |
|---|
| Isolation de base | low fire hazard |
|---|---|
| Core flexible | class 5 |
| Membres de soutien | ST = Steel, diameter in [mm] |
| Gaine extérieure | low fire hazard |
| Couleur de la gaine | noire |
| Norme pour les câbles souples de commande d'ascenseurs | EN 50214 |
|---|
| Maximum travelling height | 400 m |
|---|---|
| Suspension libre maximale | 220 m |
| Vitesse de course maximale | 12 m/s |
| Diamètre de boucle recommandé | according to table, tolerance -50/+100 mm |
| Acceleration | 1.2 m/s² |