HD-DCS MTP module, 1x MTP on 6x LCD/PC, OS2
for HD-DCS modular panels
für OS2
Variantes de produits et stock
Numéro d'article | Inventaire | Produit | Dimensions extérieures | Couleur | Matière | Poids [kg] | Unité d'emballage | GTIN / EAN |
---|---|---|---|---|---|---|---|---|
473522 | HD-DCS MTP module, 1x MTP on 6x LCD/PC, OS2 | 13 mm x 88 mm x 118 mm | noire | Polycarbonate (PC) | 0.08 kg | 1 pc. | 40393910145366 |
Spécifications techniques
Polycarbonate (PC) housing with press-fit cover (sealed).
At the rear these HD-DCS modules have one MTP coupler which is routed to the front couplers (6LCD) by way of an internal fanout.
Front couplers with integrated, automatic transparent dust shutters.
System | HD-DCS |
---|---|
Entièrement équipé | oui |
Capacité d'acceptation | 12 fibres |
Code couleur de la fibre | IEC 60304 |
---|---|
Adaptateur, face avant | 1 x 6LCD, bleu |
Adapter material, front side | Polymère |
Protégé contre la poussière, avant | oui |
Protection laser avant | non |
Protégé contre la poussière et le laser, avant | Obturateur intérieur, translucide |
Matériau de la manche, face avant | Zircone (ZrO2) |
Connecteurs, face avant | 12 x LC/PC 0° |
Matériel de virole, avant | Zircone (ZrO2) |
Adaptateur, face arrière | 1 x MTP, vert, Type A (key up/key down) |
Adapter material, rear side | Polythermide |
Type d'adaptateur, face arrière | Type A (key up/key down) |
Protégé contre la poussière, arrière | oui |
Protection laser, arrière | oui |
Protégé contre la poussière et le laser, arrière | Bouchon anti-poussière |
Connecteurs, face arrière | 1 x MTP12 female Elite APC 8° |
Matériel de virole, arrière | Résine de sulfure de polyphénylène |
Housing, equipped with 1x 6LCD adapter with automatic transparent dust protection caps and ceramic sleeves on the front. Rear fitted with 1 MTP adapter (Type A). 1 module fanout (HighP): with 12 fibres, 1x MTP Elite® (female) on 12x LC (ceramic ferrules). |
Application |
HD-DCS MTP® modules are suitable for all high-density and high-performance applications with duplex signals, particularly in the data centre environment. They find modular application in the slots of the HD-DCS modular panels (19”/1U) in which they can be inserted from the front. They are used to accept pre-assembled MTP trunk cables. Packing densities of up to 144 fibres on 1U are achieved with these modules. They are assembled to a very high quality and guarantee optimum values for optical performance (IL/RL). |
---|
As high-performance patch cables for high-density solutions Datwyler recommends the HD-DCS LCD Uniboot patch cables with push-pull rods. |
Perte d'insertion (IL), maximal, avant | 0.25 dB |
---|---|
Perte d'insertion (IL), typique, avant | 0.12 dB |
Perte de retour (RL), minime, avant | 50 dB |
Retour perte (RL), typique, avant | 55 dB |
Perte d'insertion (IL), maximal, arrière | 0.30 dB |
Perte d'insertions (IL), typique, arrière | 0.15 dB |
Perte de retour (RL), minime, retour | 65 dB |
Perte de retour (RL), typique, retour | 70 dB |
Type de fibre | E9/125 G.652.D BLO |
Norme LC (IEC) | IEC 61754-20 |
---|---|
Norme MTP (IEC) | IEC 61754-7, IEC 61755-3-31, IEC 61755-3-32 |
Documentation
-
Fiche technique
Télécharger PDF [ 71,274 KO ]
-
Fiche technique
Télécharger PDF [ 75,188 KO ]
-
Fiche technique
Télécharger PDF [ 71,741 KO ]
-
Fiche technique
Télécharger PDF [ 72,209 KO ]
-
Fiche technique
Télécharger PDF [ 72,05 KO ]
-
Fiche technique
Télécharger PDF [ 75,187 KO ]
-
Fiche technique
Télécharger PDF [ 74,285 KO ]
-
Tender text
Télécharger WORD [ 29,696 KO ]