Multimode fibre, G50/125/250, OM5

bend optimized
IEC 60793-2-10 Type A1-OM5b, ISO/IEC 11801 OM5, TIA/EIA 492AAAE

1 Core
2 Cladding
3 Coating

Technical specifications

Bend insensitive fibre with enhanced macrobending features, particularly recommended for high-performance transmissions in the 850-950 nm wavelength. The geometrical, optical and mechanical specifications meet or exceed all relevant international standards.
Numerical aperture tolerance - 0.015
Numerical aperture tolerance + 0.015
Numerical Aperture 0.200
Maximum core non-circularity [%] 5.0 %
Coating diameter [µm] 242 +/- 5
Maximum cladding/Coating concentricity error [µm] 10 µm
Test load [kpsi] 100 kpsi
Core diameter [µm] 50.0 +/- 2.5
Cladding diameter [µm] 125.0 +/- 1.0
Maximum core/cladding concentricity error [µm] 1.5 µm
Maximum cladding non-circularity[%] 1.0 %
In Premises cabling for LAN backbones (Campus and Vertical/Riser cabling) as well as in Data Centres.
Fiber specifications IEC 60793-2-10 Type A1-OM5b, ISO/IEC 11801-OM5, ITU-T G.651.1, TIA/EIA 492AAAE
Cabling standards ISO/IEC 11801-1, EN 50173-1