FO Indoor FTTH DLT / J-B(ZN)H, Cca
up to 4 fibres, FRNC/LSZH sheath, Euroclass Cca
metall-free, gel-free loose tube, flame retardant
1 Fibres
2 Loose tube
3 Aramid yarn
4 FR/LS0H sheath
Product variants & stock
Article No. | Stock | Fibres per loose tube | Number of used loose tubes | Product | Reaction to fire | Outer sheath colour | Number of fibres | Fibre type | Fibre category | Outer sheath diameter [mm] | Bending radius [mm] | CU rate [kg/km] | Weight [kg/km] | Tensile load [N] | Crush resistance short term [N] | Crush resistance continuous [N] | Fire load [kWh/m] | Packing unit | GTIN / EAN |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
19733300CZ | 2 | 1 | FO Indoor FTTH DLT 1x2 | Cca-s1a,d1,a1 | yellow | 2 | E9/125 G.652.D BLO | OS2 | 2.2 | 20 | 0 | 5.1 | 400 | 500 | 200 | 0.021 | by the metre | 40393910410112 | |
19727700CZ | 4 | 1 | FO Indoor FTTH DLT 1x4 | Cca-s1a,d1,a1 | yellow | 4 | E9/125 G.652.D BLO | OS2 | 2.2 | 20 | 0 | 5.3 | 400 | 500 | 200 | 0.021 | by the metre | 40393910231229 |
Technical specifications
Easy to handle fibre optic cable with up to 4 optical fibres.
Very small outer diameter (2.2 mm).
Dry loose tube (DLT) for easy removal. No more fibre cleaning necessary.
Flame retardant halogen-free FR/LS0H sheath. Very low fire load.
Robust sheath for easy installation into tube systems occupied by other cables.
Maximum number of fibres | 4 |
---|---|
Standard delivery length [m] | 1000 m |
Installation temperature | -10 °C - +50 °C |
Storage temperature | -20 °C - +60 °C |
Operating temperature | -20 °C - +60 °C |
Imprint | DATWYLER FO Indoor FTTH DLT / J-B(ZN)H «No. of fibres» «Fibre type» «Batch no.» Cca-s1a,d1,a1 MADE IN SWITZERLAND «Meter marks» |
Field of application | Indoor |
Tube colour(s) | red |
---|---|
Outer sheath material | FRNC/LSZH |
Indoor cabling for Fibre to the Home (FTTH) applications. Indoor cabling for data network and building automation applications. Connection cable between building entry point (BEP) and FO data outlet. Suitable for laying in cable trays, ducts and vertical shafts. Can be spliced in wall mounted distribution boxes and in FO data outlets. |
Tensile performance | IEC 60794-1-21 E1 |
---|---|
Crush resistance | IEC 60794-1-21 E3 |
Impact | IEC 60794-1-21 E4 |
Repeated bending | IEC 60794-1-21 E6 |
Torsion | IEC 60794-1-21 E7 |
Bend | IEC 60794-1-21 E11 |
Temperature cycling | IEC 60794-1-22 F1 |
Reaction to fire | EN 13501-6 |
Euroclass | Cca |
Smoke density | IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2 |
Zero halogen no corrosive gases | IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2 |
Flame propagation | IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2 |