FH - FRNC

High rise - travelling height maximum 400m

Drawing according to article number 192898; Type 8866-F

04_Propagation 05_Spread- 06_Density 03_LS0H

Product variants & stock

Article No. Stock ProductCable designCU rate [kg/km]Weight [kg/km]GTIN / EAN
185126
8585-F30 G 1.00 + 1 x 4 x 0.34 mm² (STQ)335106040393910077346
191114
8859-F12 G 2.00 + 30 x 1.00 + 7 x 2 x 0.50 (FTP) + 3 x 4 x 0.50 mm² (STQ)698192940393910069679
192313
8880-F12 G 0.75 + 24 x 2 x 0.75 mm² (FTP) + 1 CX 75 Ω532188340393910067774
191483
8866-F10 G 2.50 + 7 x 1.50 + 6 x 1.00 + 12 x 2 x 0.75 mm² (FTP) + 4 FO G50/125 µm616218440393910069297

Technical specifications

Elevator suspension cable for indoor and panoramic elevators
Acceleration 1.2 m/s²
Maximum running speed 12 m/s
Maximum travelling height 400 m
Maximum free suspension 220 m
Recommended loop diameter according to table, tolerance -50/+100 mm
Pair/quad various colours or black with white numbers
Core black, white numbered, G = with green-yellow core(s)
Operating temperature -15 °C - +70 °C
Imprint varios colores o impreso en negro con numeración en blanco
Rated voltage Uo/U according to table
To comply with the correct installation procedures please refer to the Datwyler installation manual which is available separately.
Core insulation low fire hazard
Core flexible class 5
Supporting members ST = Steel, diameter in [mm]
Outer sheath material low fire hazard
Outer sheath colour black
Standard for flexible lift control cables EN 50214

Documentation