CU SPE 1P flex Industrial FRNC UL
Industrial data cable, S/FTP, AWG22/7, Euroclass Eca
600 MHz
1 Inner conductor: AWG22/7, stranded copper wires
2 PE insulated conductor: Ø 1.7 mm
3 Screen (pair): Alu PETP foil
4 Overall screen: Tinned braided copper
5 Outer sheath: FRNC/LSZH
Product variants & stock
Download
Article No. | Stock | Product | Reaction to fire | Dimensions n x p x [mm² (AWG)] | Outer sheath colour | Outer sheath dimensions [mm] | CU rate [kg/km] | Weight [kg/km] | Packing unit | GTIN / EAN |
---|---|---|---|---|---|---|---|---|---|---|
19471300EK | CU SPE 1P AWG 22/7 | Eca | 1 x 2 x 0.35 (AWG22/7) | grey | 5.1 | 16.1 | 34 | 1000 m drum | 40393910231427 |
Technical specifications
Electrically and mechanically high-quality 1-pair cable for Single Pair Ethernet (SPE) application and for frequencies up to 600 MHz.
Complies and exceeds the requirements of ISO/IEC 11801-1 Amd 1 “General Requirements”, ISO/IEC 11801-3 Amd 1 “Industrial Premises”, ISO/IEC 11801-6 Amd 1 “Distributed Building Services”, TR 11801-9906 “one pair channel” and IEC 61156-11 “Symmetrical single pair cables with transmission characteristics up to 600 MHz”.
Excellent shielding effectiveness due to individually screened pair and overall copper braid.
Compatible with all current Single Pair Ethernet connecting hardware in accordance with IEC 63171 series.
Complies and exceeds the requirements of ISO/IEC 11801-1 Amd 1 “General Requirements”, ISO/IEC 11801-3 Amd 1 “Industrial Premises”, ISO/IEC 11801-6 Amd 1 “Distributed Building Services”, TR 11801-9906 “one pair channel” and IEC 61156-11 “Symmetrical single pair cables with transmission characteristics up to 600 MHz”.
Excellent shielding effectiveness due to individually screened pair and overall copper braid.
Compatible with all current Single Pair Ethernet connecting hardware in accordance with IEC 63171 series.
Maximum tensile strength | 25 N |
---|---|
AWG | 22 |
Solid / Flex | Stranded wire (flexible) |
Minimum bending radius (permanently installed) | 22 mm |
Flexible data cable with stranded conductor suitable for patch cords and equipment cords in a Single Pair Ethernet environment. For the transmission of digital and analogue data, voice and video signals. Suitable for IP based 2-wire bus applications with conductor wire size of AWG 22. Applicable for Power over Data Line (PoDL). |
Category | Single pair Ethernet |
---|---|
Loop resistance at 20 °C | 110 Ω/km |
Operating capacity | 43 pF/m |
Impedance at 100 MHz, ±5Ω | 100 Ω |
NVP % | 78 |
Shielding | shielded |
Coupling attenuation | 85 dB |
Segregation class | d |
Installation temperature | 0 °C - +50 °C |
---|---|
Operating temperature | -20 °C - +70 °C |
Wire colour | white/blue |
Imprint | DATWYLER «cable type» «additional text» «UL Info» «batch number» «meter marks» |
Field of application | Single pair Ethernet |
Reaction to fire | EN 13501-6 |
---|---|
Euroclass | Eca |
Smoke density | IEC 61034-1/-2, EN 61034-1/-2 |
Zero halogen no corrosive gases | IEC 60754-1/-2, EN 60754-1/-2 |
Flame propagation | IEC 60332-1-2, EN 60332-1-2 |
Cables standard | ISO/IEC 61156-11 |
Cat./Class | Single pair Ethernet SPE and IEC 61156-11 guaranteed |
PoDL (PoE) | IEEE 802.3bu |
UL certification | UL 444, CMG |
Outer sheath material | FRNC/LSZH |
---|