CU 6060 4P
Data cable, S/FTP, Category 6, AWG23, Euroclass Cca
300 MHz
This product is not available in your region!
1 Inner conductor: AWG23 Bare copper wire
2 PE insulated conductor: 1.3 mm Ø
3 Screen (pair): Alu PETP foil
4 Overall screen: Tinned braided copper
5 Outer sheath: FRNC/LS0H













Product variants & stock
Download
Article No. | Stock | Product | Reaction to fire | Dimensions n x p x [mm (AWG)] | Outer sheath dimensions [mm] | CU rate [kg/km] | Weight [kg/km] | Fire load [kWh/m] | Packing unit | GTIN / EAN |
---|---|---|---|---|---|---|---|---|---|---|
19432800CL | CU 6060 4P | Cca-s1a,d1,a1 | 4 x 2 x 0.55 (AWG23) | 7.6 | 26.4 | 47.5 | 0.14 | 500 m drum | 40393910023145 |
Technical specifications
Electrically and mechanically superior quality Cat.6 data cable - exceeds the requirements of ISO/IEC 11801, IEC 61156-5, EN 50173-1 and EN 50288-5-1.
Excellent shielding effect due to individually screened pairs and overall copper braid.
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.
Excellent shielding effect due to individually screened pairs and overall copper braid.
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.
Tensile strength (4P) | 95 N |
---|---|
Minimum bending radius (during installation) | 65 mm |
Minimal crush resistance / 10cm | 1000 N |
Minimum number of impacts | 10 |
AWG | 23 |
Solid / Flex | Solid wire |
Minimum bending radius (permanently installed) | 30 mm |
Data cable for structured premises cabling. For the transmission of digital and analogue voice, video and data signals. Suitable for all ICT network applications up to class E applications (250 MHz) in accordance with EN 50173-1 and ISO/IEC 11801. Applicable for Power over Ethernet (PoE) / PoE+ / 4PPoE. |
Category | Cat.6 |
---|---|
GBit/s | Up to 10 Gbit/s |
Loop resistance at 20 °C | 146 Ω/km |
Operating capacity | 42 pF/m |
Impedance at 100 MHz, ±5Ω | 100 Ω |
NVP % | 80 |
Delay skew | 4 ns/100 m |
Shielding | shielded |
Near end unbalance attenuation LCL at 1-600 MHz | 40 dB |
Transfer impedance 1/10/30 MHz | < 9/12/30 mΩ/m |
Coupling attenuation | 70 dB |
Segregation class | c |
Installation temperature | 0 °C - +50 °C |
---|---|
Operating temperature | -20 °C - +60 °C |
Wire colour | white/blue, white/orange, white/green, white/brown, according to IEC 60189 and IEC 60708 |
Imprint | DATWYLER «cable type» «additional text» «batch number» «meter marks» |
Field of application | Indoor |
Reaction to fire | EN 13501-6 |
---|---|
Euroclass | Cca |
Smoke density | IEC 61034-1/-2, EN 61034-1/-2 |
Zero halogen no corrosive gases | IEC 60754-1/-2, EN 60754-1/-2 |
Flame propagation | IEC 60332-1-2, EN 60332-1-2 |
Flame spread | IEC 60332-3-24, EN 60332-3-24 |
Cables standard | ISO/IEC 61156-5, EN 50288-5-1 |
Cat./Class | Cat.6 / Class E |
PoE | IEEE 802.3at |
Outer sheath material | FRNC/LSZH |
---|---|
Outer sheath colour | orange |